Soft hydrogel actuators that interface with living tissues must combine reliable attachment with programmed disengagement after completing their function. Here, we introduce a programmed-reopening bilayer hydrogel actuator with an intrinsic material off-switch. Using multilayer digital light processing (DLP), we fabricate poly(N-isopropylacrylamide)/bovine serum albumin–poly(ethylene glycol) diacrylate(Trypsin) (PNIPAM/BSA–PEGDA(Trypsin)) bilayers in which the PNIPAM layer drives closure at physiological temperature (37°C), while the trypsin-loaded BSA–PEGDA layer undergoes proteolysis-programmed softening. The progressive loss of stiffness relaxes curvature and reopens the device. We quantify print-parameter-dependent actuation, trypsin encapsulation and release, retained proteolytic activity, and time-dependent softening of the enzyme-programmed layer. Lap-shear testing and microscopy characterize the bonded bilayer interface. Mechanistic anchoring is visualized on a mucin-mimicking interface by microscopy and time-lapse imaging, and ex vivo tests on porcine small intestine demonstrate robust retention under controlled dynamic motion with millinewton-scale gripping forces. These findings establish a materials strategy for programming the functional lifetime and reopening of tissue-interfacing hydrogel actuators. Statement of Significance Tissue-interfacing hydrogel actuators are promising for gastrointestinal retention and local therapy, but most existing systems deform in one direction and lack an intrinsic mechanism for disengagement. We introduce a programmed-reopening bilayer actuator in which proteolysis-programmed mechanical relaxation acts as an internal off-switch. Multilayer digital light processing (DLP) produces poly(N-isopropylacrylamide)/bovine serum albumin–poly (ethylene glycol) diacrylate (Trypsin) (PNIPAM/BSA–PEGDA(Trypsin)) bilayers that close at physiological temperature, release active trypsin, and progressively reopen as the protein–polymer layer softens. The study integrates release, mechanical relaxation, preliminary cytocompatibility, mucin-interface anchoring, and ex vivo retention on porcine intestine. It establishes a materials design principle for programming actuator lifetime and termination, advancing autonomous and transient soft biomedical devices.
No takes yet. Share an insight, caveat, or question.
Mo et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: