Reliable respiration rate estimation from WiFi channel state information (CSI) remains challenging due to multipath interference and orientation-dependent signal degradation. This study aimed to provide a two-stage mathematical framework that exploits the statistical properties of complex-valued CSI for robust respiration estimation. First, a binary frequency-domain mask was applied to the complex CSI ratio to isolate respiration-induced components. Motivated by the zero-mean Gaussian characteristics of ambient noise, the proposed spectral reconstruction separated periodic respiratory signals from stochastic interference through inverse fast Fourier transform reconstruction. Second, a dual principal component analysis (PCA) scheme was introduced. The first-stage PCA aggregated complementary respiration-related information across multiple subcarriers in the complex domain to mitigate multipath effects, whereas the second-stage PCA extracted a real-valued respiration waveform by projecting the real-imaginary representation of the fused complex time series onto the principal-component direction of maximum variance. Experiments involving 11 participants across four sleep postures and three antenna deployment configurations yielded a mean absolute error of 0.10 breaths per minute, outperforming representative existing methods. The results indicate that preserving amplitude-phase coupling in the complex domain improves the robustness of respiration signal extraction.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: