Answers are grounded in this paper and cite their sources.
Hydrogen is being extensively investigated as a carbon-free energy carrier, particularly for fuel-cell vehicles and long-term energy storage. Because H2 can form explosive mixtures in air at concentrations as low as 4%, its safe use requires inexpensive, low-power sensors capable of reliable detection. Here, we investigated ribbon-like palladium–platinum nanostructures, referred to as PdPt nanoribbon/nanosheet hybrid structures (PdPt NR/NSs), for room-temperature chemiresistive H2 sensing. Sensors were fabricated by drop-casting dispersions of the PdPt NR/NSs onto interdigitated electrodes. The sensor resistance increased upon exposure to H2 because of hydrogen uptake by the PdPt NR/NSs and formation of a hydride phase with higher resistivity than the hydrogen-free alloy. The best-performing sensor, Pd5Pt8, was prepared using a 5:8 Pd:Pt precursor mass ratio, which yielded a measured Pd:Pt atomic ratio of approximately 1.3:1. This sensor showed a response time of 16 s and a response of 6.0% to 1 vol% H2 in air. H2 concentrations as low as 100 ppm were readily detected while maintaining a positive resistance response. These results demonstrate the potential of PdPt NR/NS architectures for low-power H2 detection at ambient temperature.
No takes yet. Share an insight, caveat, or question.
Mohsenifard et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: