Key result
Elevated myosin light chain-1 is linked to ~111% higher risk of death or MI.
Why the study?
There are few data assessing the value of sensitive and specific cardiac markers as long-term predictors in patients with chest pain at risk of acute MI.
Cohort (n=208)
Odds Ratio: 2.11 (95% CI 1.14–3.93)
MLC-1 elevation may refine long-term risk stratification after chest pain; leaves open whether it adds value beyond modern hs-cTn or changes management.
BACKGROUND: Sensitive and specific cardiac markers convey important short-term prognostic information about patients with an acute coronary syndrome. There are, however, few data assessing their value as long-term predictors. HYPOTHESIS: The aim of the current study was to assess the relative value of three such markers and clinical characteristics in determining the long-term prognosis of patients with chest pain. METHODS: Cardiac troponin I (cTnI), myosin light chain-(MLC-1), and creatine kinase-MBmass levels were obtained on admission (0 h) and at 4, 8, 16, and 24 h in 208 patients with chest pain. Eligible subjects were determined, at the time of hospital admission, to be at >7% risk of acute myocardial infarction (MI), but without new ST-segment elevation on their presenting electrocardiogram. Follow-up was performed a median of 28 (range 1-46) months later. The primary study endpoint was death or nonfatal MI, subsequent to the index admission. RESULTS: Cardiac TnI levels > or = 0.2 ng/ml (odds ratio [OR] 1.93, 95% confidence interval [CI] 1.09-3.40) and MLC-1 levels > or = 1 ng/ml (OR 3.24, 95% CI 1.83-5.73) were both significant predictors of death or MI during long-term follow-up; MLC-1 was, however, the only independent biochemical predictor (OR 2.11,95% CI 1.14-3.93). CONCLUSIONS: Both cTnl and MLC-1 predict the long-term outcome of patients with chest pain, but, in this cohort, MLC-1 proved to be a better predictor of mortality and nonfatal acute MI.
No takes yet. Share an insight, caveat, or question.
Hillis et al. (2003) conducted a cohort in chest pain (n=208). Elevated myosin light chain-1 (MLC-1) levels ≥ 1 ng/ml vs. MLC-1 levels < 1 ng/ml was evaluated on death or nonfatal MI, subsequent to the index admission (OR 2.11, 95% CI 1.14-3.93). In patients with chest pain, elevated myosin light chain-1 (≥1 ng/ml) was an independent predictor of long-term death or nonfatal MI (OR 2.11; 95% CI 1.14-3.93).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: