The power-energy performance of supercapacitors is usually visualized by the Ragone plot of (gravimetric or volumetric) energy density vs power density. The energy is commonly computed from E = CV 2 /2, and the power from P = E /Δ t , which assume RC -based models. In this study, we investigate the energy-power profiles of two commercial supercapacitors discharged with three different types of loads: (i) constant current, (ii) constant power, and (iii) constant resistive load. The energy is computed as per the definition from the time-integral of its instantaneous power, i.e. E ( t ) = ∫ p ( t ) dt with p ( t ) = i ( t ) v ( t ). In doing so, we do not assume any specific model a priori, and we highlight the fact that supercapacitor performance depends on the type of load it supplies. We also model the experimental Ragone plot using a fractional-order model composed of a resistance and a constant phase element, and show its superiority over the standard RC model.
No takes yet. Share an insight, caveat, or question.
Allagui et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: