Answers are grounded in this paper and cite their sources.
Flame-wall interaction is crucial with the emergence of high-power downsized combustion chambers. Wall thermal management can be enhanced by using parietal cooling air films, but the injection of this additional air also affects pollutant emissions. This experimental study aims to combine planar laser-based imaging diagnostics to characterize the effect of a cooling air film – via a systematic variation of the air film momentum – on the emission of carbon monoxide (CO). Experiments are conducted with a turbulent premixed methane/air flame interacting with a cooling air film generated by a splash-cooling system. Global exhaust measurements indicate a significant increase of the CO emissions when the cooling air momentum is increased. To identify the underlying local mechanisms, CO and OH are simultaneously probed by planar laser-induced fluorescence. For all cases, the CO production area is clearly identified in the vicinity of the flame front. When the flame reactivity is reduced, large CO levels are retrieved near the wall, being spatially more distributed. The location of the air film is achieved by seeding the flow with inert NO. Simultaneously measured with OH by means of planar laser-induced fluorescence, the flame is more prone to be in direct contact with the air film when its momentum is increased, leading to a reduced flame reactivity through a lack of incoming reacting mixture. The CO produced by the flame is thereby convected into the air film, with no possibility to be oxidized. Novelty and significance statement: Recognized to be intrinsically spatial and case dependent, flame-cooling air interaction is studied, for the first time, with the determination of experimental 2D distribution of near-wall CO by planar laser-based fluorescence (PLIF) measurements. Simultaneously coupled with OH-PLIF, novel joint spatial correlations enable to highlight the CO distribution with respect to the flame topology. Moreover, the air film topology is obtained by PLIF measurements with seeded NO, with fruitful insights on the effect of the air film momentum on CO emissions. Compared to flame-wall interaction or aerothermal studies, this case is more realistic of current combustion chambers. The methodology, dataset, and physical insights will be beneficial to the combustion community, to challenge current turbulent combustion models, and to improve the design of low-pollutant combustor wall cooling technologies.
No takes yet. Share an insight, caveat, or question.
Xavier et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: