Key result
Higher plasma BH4/BH2 ratio correlates with better endothelial function measured by FMD.
Why the study?
There have been no reliable plasma markers for endothelial dysfunction despite the use of endothelium-dependent vasodilatation as a marker.
Cross-Sectional (n=163)
Single-blind (ultrasound observers blinded to clinical data)
Randomized for statin sub-study only
No
Answers are grounded in this paper and cite their sources.
Supports BH4/BH2 ratio as endothelial biomarker in observational data; hypothesis-generating, requires prospective validation before clinical use.
BACKGROUND: Although endothelium-dependent vasodilatation has been used as a marker of endothelial dysfunction (ED), there have been no reliable plasma markers for ED. Oxidative stress, which is a major determinant of ED, oxidizes tetrahydrobiopterin (BH4), an essential cofactor of endothelial type nitric oxide synthase (eNOS), and resulted in the relative deficiency of BH4. METHODS AND RESULTS: In 163 patients with cardiovascular disorders, the plasma levels of BH4 and 7, 8-dihydrobiopterin (BH2) by high performance liquid chromatography were measured and compared with the flow-mediated (FMD) vasodilatory response of the brachial artery, which was measured by ultrasonography. The effects of atorvastatin on plasma pteridine levels and FMD were examined in patients with multiple coronary risk factors. There was a positive relationship between FMD and plasma BH4 levels and a negative relationship between FMD and plasma BH2 levels. Subsequently, a strong positive relationship between FMD and the BH4/BH2 ratio (r=0.585, P<0.0001) was found. Although we did not find any significant relationship between pteridine levels and individual traditional risk factors, the BH4/BH2 ratio in patients with more than 2 risk factors showed significant reductions compared with that in those without risk factors. Statin treatment improved FMD in association with an increase in the plasma BH4/BH2 ratio. CONCLUSIONS: Plasma pteridine levels were associated with endothelial dysfunction in cardiovascular disorders.
No takes yet. Share an insight, caveat, or question.
Takeda et al. (2009) conducted a cross-sectional in Cardiovascular disorders (n=163). Plasma BH4/BH2 ratio was evaluated on Correlation between flow-mediated vasodilatation (FMD) and plasma BH4/BH2 ratio (r=0.585, p=<0.0001). The plasma BH4/BH2 ratio demonstrated a strong positive correlation with flow-mediated vasodilatation (r=0.585, P<0.0001), indicating its potential as a biomarker for endothelial dysfunction.
Synapse has enriched 10 related papers. Consider them for comparative context: