Key result
Bachmann's bundle pacing is linked to ~81% less ventricular pacing compared to RAA pacing.
Why the study?
Patients with sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation, and the influence of atrial pacing site on conduction and ventricular pacing is unclear.
Cohort (n=96)
Bachmann’s bundle pacing was associated with shorter conduction times and less ventricular pacing; leaves open clinical benefit versus appendage pacing in randomized trials.
BACKGROUND: Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. OBJECTIVES: This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. MATERIAL AND METHODS: The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. RESULTS: No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). CONCLUSIONS: Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.
No takes yet. Share an insight, caveat, or question.
Sławuta et al. (2016) conducted a cohort in Sick sinus syndrome (n=96). Bachmann's area pacing vs. Right atrial appendage pacing was evaluated on Percentage of ventricular pacing (p=<0.01). Bachmann's bundle pacing resulted in a significantly lower percentage of ventricular pacing compared to right atrial appendage pacing (4% vs 21%, p<0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: