Key result
Bachmann's bundle pacing matches multisite hemodynamics, while coronary sinus pacing reverses atrial contraction causing pacemaker syndrome.
Why the study?
Does single-site Bachmann's bundle pacing or coronary sinus pacing improve atrial synchrony compared to multisite atrial pacing in patients with sinus node dysfunction and recurrent AF?
Does single-site Bachmann's bundle pacing or coronary sinus pacing improve atrial synchrony compared to multisite atrial pacing in patients with sinus node dysfunction and recurrent AF?
Single-site Bachmann's bundle pacing provides comparable hemodynamics and better atrial contraction synchrony than multisite atrial pacing, whereas coronary sinus pacing induces right heart pacemaker syndrome.
Answers are grounded in this paper and cite their sources.
Bachmann's bundle pacing may simplify atrial resynchronization in sinus node dysfunction with AF; extends RCT evidence on site-specific pacing while discouraging coronary sinus use.
BACKGROUND: It has been proposed that multisite atrial pacing (MSAp) restores atrial electrical activation and prevents atrial fibrillation recurrence; however, single-site Bachmann's bundle pacing (BBp) has also been reported as providing effective atrial resynchronization. Coronary sinus pacing (CSp) leads to reversed impulse propagation within the atria. METHODS AND RESULTS: Acute echocardiographic examination was performed in 15 healthy subjects, and in 25 patients with sinus node dysfunction and recurrent atrial fibrillation during MSAp (atrial leads in the BB area and CS ostium), and single-site BBp and CSp. Regional atrial synchrony was assessed by tissue Doppler echocardiography. Pacing mode had no effect on stroke volume. CSp resulted in right atrial filling diminution, shortened mechanical atrioventricular delay in the right heart and diminished right ventricular inflow. The magnitude of reversion of the physiological right-to-left atrial contraction sequence was most prominent during CSp (15+/-11, 12+/-23, 3+/-21, 42+/-23 ms; control, MSAp, BBp, CSp respectively, P<0.0001). BBp provided the best atrial contraction synchrony, and had a comparable effect on global cardiac function to MSAp. CONCLUSIONS: Single-site BBp provides comparable hemodynamics to MSAp and is sufficient to restore atrial contraction synchrony. Single-site CSp induced echocardiographic pacemaker syndrome in the right heart.
No takes yet. Share an insight, caveat, or question.
Dąbrowska-Kugacka et al. (2010) studied Sinus node dysfunction and recurrent atrial fibrillation (n=40). Single-site Bachmann's bundle pacing (BBp) and Coronary sinus pacing (CSp) vs. Multisite atrial pacing (MSAp) and sinus rhythm was evaluated on Atrial contraction sequence (PAm-t) (p=<0.0001). Single-site Bachmann's bundle pacing provided comparable hemodynamics to multisite atrial pacing, whereas single-site coronary sinus pacing reversed the physiological atrial contraction sequence (PAm-t -42 ms vs -12 ms, p<0.0001) and induced right heart pacemaker syndrome.