Key result
During right ventricular pacing in dog hearts, the number of breakthrough sites in secondary areas was similar to sinus rhythm (113 vs 115), with 72% occurring at the exact same locations.
Why the study?
The study aimed to determine whether ventricular pacing produces multiple epicardial breakthrough sites and whether their number and location are independent of pacing site in the right ventricle.
Ventricular pacing yields multiple site-independent BKTs; leaves open relevance to human conduction or arrhythmia mapping.
In a previous investigation, epicardial recordings with 1,124 closely spaced electrodes revealed 20-35 breakthrough (BKT) sites and an equal number of separate wave fronts on the ventricular surface of exposed dog hearts during normal sinus rhythm. In the present study we tried 1) to determine whether ventricular pacing also produced multiple BKTs and wave fronts and 2) to determine whether the number and location of BKTs were, to some degree, independent of pacing site. The study mainly focused on right ventricular BKTs observed during right ventricular pacing. To test hypotheses 1 and 2 we identified many breakthrough sites during sinus rhythm in seven exposed dog hearts and then paced the heart from several BKT and non-BKT sites on the right ventricle. Epicardial potential maps and excitation time maps were obtained by using 1,124 epicardial electrodes covering the anterior right ventricle and part of the anterior left ventricle. A primary wave front spread radially for several centimeters from the pacing site, and no BKTs appeared in the areas covered by the primary wave front. In the remaining areas (secondary areas), multiple BKTs appeared; their number was close to that observed during sinus rhythm in the same areas (113 versus 115, respectively, in 12 paced beats). The majority of paced BKTs (83 out of 115, or 72%) occurred exactly at the same locations where they appeared during sinus rhythm. However, 30 right ventricular BKTs observed during sinus rhythm disappeared in the secondary areas and were replaced by approximately the same number of new BKTs. Many areas without BKTs in normal beats remained so in paced beats.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Arisi et al. (1992) studied Ventricular pacing (animal model) (n=7). Right ventricular pacing vs. Normal sinus rhythm was evaluated on Number and location of breakthrough (BKT) sites in secondary areas. During right ventricular pacing in dog hearts, the number of breakthrough sites in secondary areas was similar to sinus rhythm (113 vs 115), with 72% occurring at the exact same locations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: