Key result
Micro-bubbles account for ~88% of high-intensity transient signals detected during cardiopulmonary bypass.
Why the study?
The clinical significance of high-intensity transient signals (HITS) detected during cardiopulmonary bypass (CPB) remains controversial, particularly regarding their frequency characteristics.
Observational (n=6)
No
Answers are grounded in this paper and cite their sources.
Frequency analysis may distinguish micro-bubbles from solid emboli on TCD during CPB; leaves open validation for embolic risk stratification.
Purpose: High-intensity transient signals (HITS) are commonly detected during cardiopulmonary bypass (CPB) . However, the clinical significance of HITS during CPB is still controversial. Micro-bubbles are reported to produce HITS of more than 400-500 Hz. We attempted to elucidate the incidence of HITS exceeding 400 Hz during CPB. Methods: The subjects were 6 patients who underwent open heart surgery using CPB. HITS were detected by TC2020, PIONEER (Nicolet /EME) with a 2.0-MHz pulsed Doppler probe at the middle cerebral artery. Transesophageal echocardiography (TEE) was undertaken during the operation. Results: The total number of HITS during CPB was 1707±1392 (n=6) . Of the total HITS, 88.1±6.8% had a frequency of more than 400 Hz. On the other hand, HITS of less than 400 Hz were frequently detected at aortic cannulation, aortic decannulation and aortic cross-clamping. HITS of more than 400 Hz were detected in cases showing cardiac or aortic micro-bubbles in TEE. Conclusion: The present findings suggest that the majority of HITS during CPB reflect micro-bubbles, and that aortic manipulation may be related to the formation of solid micro-emboli. HITS frequency analysis may be useful for differentiating between micro-bubbles and solid micro-emboli formed during CPB.
No takes yet. Share an insight, caveat, or question.
Kazuhiko Hanzawa (1999) conducted an observational in Open heart surgery requiring cardiopulmonary bypass (n=6). Cardiopulmonary bypass was evaluated on Proportion of high-intensity transient signals (HITS) exceeding 400 Hz during cardiopulmonary bypass. During cardiopulmonary bypass, 88.1% of detected high-intensity transient signals had a frequency exceeding 400 Hz, suggesting that the majority of these signals reflect micro-bubbles.
Synapse has enriched 10 related papers. Consider them for comparative context: