Answers are grounded in this paper and cite their sources.
A facility capable of generating steady and oscillating flows was constructed and experiments were conducted to investigate the pressure-drop characteristics of regenerators packed with wire screens. Both the velocity and pressure-drop across the regenerator were measured. To accurately determine the correlation between pressure-drop and velocity, the experiments covered a wide range from very low to very high Reynolds numbers, Reh. The steady flow results reveal that a three-term correlation with a term proportional to Reh−1/2 in addition to the Darcy-Forchheimer two-term correlation will fit best to the data. This Reh−1/2 term accounts for the boundary layer effect at intermediate Reynolds number. The results also show that the correlation for oscillating flows coincides with that for steady flows in 1 < Reh < 2000. This suggests that the oscillating flows in the regenerators behave as quasi-steady at the frequency range of less than 4.0 Hz, which is the maximum operable oscillating flow frequency of the facility.
No takes yet. Share an insight, caveat, or question.
Hsu et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: