Key result
Artificial pneumothorax linked to ~45% shorter operative time in endoscopic LAAC and surgical ablation.
Why the study?
Securing the operative field during totally endoscopic off-pump LAA closure and surgical ablation is sometimes difficult due to narrow working space caused by elevated diaphragm or ventricles.
Does artificial pneumothorax reduce operative time in patients undergoing totally endoscopic off-pump left atrial appendage closure and surgical ablation?
Cohort (n=71)
No
Does artificial pneumothorax reduce operative time in patients undergoing totally endoscopic off-pump left atrial appendage closure and surgical ablation?
The use of an artificial pneumothorax during totally endoscopic off-pump left atrial appendage closure and surgical ablation safely and significantly reduces operative time.
Answers are grounded in this paper and cite their sources.
May shorten operative time in endoscopic LAA procedures; leaves open confirmation of safety and outcomes in randomized trials.
PURPOSE: In totally endoscopic off-pump left atrial appendage (LAA) closure and surgical ablation, securing the operative field is sometimes difficult in some patients because of a narrow working space caused by an elevated diaphragm or ventricles. In this study, we aimed to investigate the effectiveness of a method that facilitates securing the operative field using an artificial pneumothorax. METHODS: We analyzed 71 consecutive patients who underwent totally endoscopic off-pump LAA closure and bilateral pulmonary vein isolation. The factors contributing to the reduction in operative time were examined. The patients were divided into the following 2 groups according to whether or not an artificial pneumothorax was used: Group C comprised 24 patients without an artificial pneumothorax and Group A comprised 47 patients with an artificial pneumothorax. RESULTS: There were no hospital deaths or major complications. The operative time was significantly shorter in Group A (108 ± 26 minutes) than in Group C (198 ± 77 minutes) (p <0.0001). CONCLUSIONS: In totally endoscopic off-pump LAA closure and surgical ablation, an artificial pneumothorax may be useful in reducing the operative time.
No takes yet. Share an insight, caveat, or question.
Sato et al. (2025) conducted a cohort in Atrial Fibrillation (n=71). Artificial pneumothorax vs. No artificial pneumothorax was evaluated on Operative time (p=<0.0001). The use of artificial pneumothorax during totally endoscopic off-pump left atrial appendage closure and surgical ablation significantly reduced operative time from 198 minutes to 108 minutes.
Synapse has enriched 10 related papers. Consider them for comparative context: