Key result
Differential pacing shows diagnostic pitfalls in ~20% of mitral isthmus block assessments.
Why the study?
Clinically encountered pitfalls in assessing transmitral conduction block using differential coronary sinus and left atrial appendage pacing techniques during mitral isthmus linear ablation were not well characterized.
Observational (n=236)
Pitfalls in mitral isthmus block assessment via differential pacing warrant technique caution; leaves open need for validated confirmation protocols.
BACKGROUND: To identify and understand clinically encountered pitfalls in the assessment of transmitral conduction block using differential coronary sinus and left atrial appendage pacing techniques in patients with left mitral isthmus linear ablation. METHODS AND RESULTS: All the available assessments of mitral isthmus block were thoroughly reviewed in 271 mitral isthmus ablation procedures undertaken among 236 patients from October 2008 to April 2011. Bidirectional block was established in 186 of 271 (69%) procedures. Careful evaluation of electrograms recorded on the multipolar coronary sinus and ablation catheters was undertaken to identify and understand the characteristics of pitfall, if any. Pitfall was encountered in 55 of 271 (20%) procedures among 51 patients and categorized into 6 types (types 1, 3, 4, and 5 led to spurious diagnosis of block; types 2 and 6 led to erroneous diagnosis of absence of block). There were 14, 10, 17, 2, 15, and 3 (total=61) cases of pitfall types 1 through 6, respectively. Operator recognized 42 of 61 (69%) pitfalls intraprocedurally. Recognition of types 1 and 5 was difficult because of indiscernible electrograms at usual amplifier settings or presence of slow conduction mimicking block. CONCLUSIONS: Every fifth assessment of bidirectional block across mitral isthmus linear lesion using differential coronary sinus and left atrial appendage pacing techniques encounters a pitfall, which can lead to erroneous clinical diagnosis of block or absence of block. Recognition of pitfall during the procedure is feasible and necessitates careful distinction of far-field left atrium from the local coronary sinus electrograms besides appropriate adjustments in catheter position and pacing outputs.
No takes yet. Share an insight, caveat, or question.
Shah et al. (2012) conducted an observational in Patients undergoing left mitral isthmus linear ablation (n=236). Assessment of mitral isthmus block using differential pacing techniques was evaluated on Encounter of a pitfall during assessment of mitral isthmus block. Assessment of bidirectional block across mitral isthmus linear lesions using differential pacing techniques encountered a pitfall in 20% of procedures, which can lead to erroneous diagnoses.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: