This study investigates the performance of the γ-CUBE preclinical SPECT scanner to optimize acquisition and reconstruction protocols for theranostic preclinical studies, and to determine the minimum administered activity of a novel 177 Lu-labelled peptide in a mouse cancer model without compromising image quality. System performance was evaluated in terms of uniformity, spatial resolution and contrast-to-noise ratio (CNR) using syringes and Derenzo phantoms, comparing 177 Lu with 99m Tc. Three interchangeable collimators (general-purpose-rat (GP-R), general-purpose-mouse (GP-M) and high-sensitivity-mouse (HS-M)) were tested by varying the number of iterations of the reconstruction algorithm. Quantitative accuracy for 177 Lu was determined at 50 iterations using a biomimetic mouse phantom and polypropylene tubes filled with activity concentrations ranging from 0.095 to 2.36 MBq/ml. Threshold injection activity was estimated in three tumour-bearing mice injected with 16.0 ± 1.3 MBq of 177 Lu-labelled peptide and scanned with HS-M collimator at different time points post-injection. Lower activities (1.6–12 MBq) were simulated by retrospective reconstructions. Tumour CNR at 48 and 168 h post-injection was calculated, and image quality was assessed by five independent readers using a 5-point scale. Integral uniformity with 99m Tc was 18.3% (GP-R), 23.6% (GP-M) and 17.3% (HS-M) at 50 iterations. Increasing iterations degraded uniformity, with 99m Tc consistently showing superior values compared to 177 Lu. GP-M collimator resolved all Derenzo rods (down to 1 mm) for both radionuclides, HS-M resolved rods ≥ 1.6 mm at 500 iterations and GP-R collimator resolved rods ≥ 1.4 mm for 99m Tc and ≥ 2 mm for 177 Lu at 500 iterations. The HS-M collimator provided superior quantitative accuracy (> 90%) for all tested activity concentrations. Tumour CNR worsened with reducing injected activity. 8 MBq was identified as the threshold to obtain good image quality up to 7 days post-injection, while 4 MBq was acceptable for short-term studies (< 48 h). The γ-CUBE system offers versatile performance for imaging with both 99m Tc and 177 Lu. The HS-M collimator is recommended for low-activity studies, and 50 iterations represents the best compromise for routine applications. Optimization analysis confirmed that in the experimental paradigm used for the study the injected activity of 177 Lu-peptide can be significantly reduced while maintaining adequate image quality for longitudinal biodistribution studies.
No takes yet. Share an insight, caveat, or question.
Tosoni et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: