High-performance wafer alignment is a cornerstone of the stringent overlay accuracy required in integrated circuit manufacturing. However, conventional alignment techniques often struggle with process-induced variations and signal noise. Building on phase grating alignment, we present a method that combines double diffraction by the same grating with vortex beam interferometry. Our approach incorporates two main advances. First, a double-pass optical configuration causes the diffracted beams to interact with the alignment mark twice, thereby enhancing the displacement-induced phase difference. Second, by exploiting the interference of conjugate vortex beams, the measurement of a microscopic phase change is converted into the measurement of a macroscopic rotation angle of the interference pattern, providing inherent immunity to common mode noise. We experimentally validated the concept and achieved a strong linear response (R 2 > 0.998) and a measurement repeatability better than 1.1 nm (1σ). The proposed technique offers a route for high accuracy wafer alignment and shows strong potential for applications in DUV and EUV lithography systems.
No takes yet. Share an insight, caveat, or question.
Zhou et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: