Q How do you measure intracranial pressure when an external ventricular drain is ordered at a negative number?A Joan Walsh, DNP, APRN, CNS, CCNS-BC, CNRN, SCRN, replies:External ventricular drains (EVDs) are used in the critical care setting for cerebrospinal fluid (CSF) diversion and intracranial pressure (ICP) monitoring. Patients with neurologic impairments such as aneurysmal subarachnoid hemorrhage, traumatic brain injury, intraventricular hemorrhage, and hydrocephalus often require EVDs as part of their care.1–3 The drainage catheter is generally placed in the right lateral ventricle to avoid the speech and language centers of the brain.3 Drainage of CSF lowers the volume within the skull and subsequently lowers ICP.The EVD catheter is connected to a drainage system composed of pressurized tubing, a system stopcock located at 0 cm of H2O, a drip chamber (burette), and a collection bag.3,4 If ICP monitoring is indicated, a pressure transducer is attached to the system stopcock; no flushing system should be used.3,5 The pressure transducer is leveled at the external landmark for the foramen of Monro (FOM), which may vary by institution, and to the zero-reference point,5 which is equivalent to the 0 cm of H2O mark on the drainage system. This process allows for accurate measurement of ICP in millimeters of mercury. The ICP and pressure waveform are displayed on the bedside monitor, which is connected by cable to the transducer.Generally, the drip chamber is placed at 0 cm of H2O or above. In certain situations—for example, low-pressure hydrocephalus—it is advantageous to set the drip chamber below 0 cm of H2O (negative pressure). The lower position promotes drainage of CSF, which may be impeded if the chamber is set at a higher level.2,6 Although some commercial ventricular drainage systems allow for negative drainage,4 others do not have this feature or do not allow the drip chamber to be set at a negative level low enough to allow adequate drainage. In these cases, a new zero-reference point must be identified to allow for drainage at the ordered negative level. Although necessary, changing the zero-reference point can be confusing and increases the risk of error when transducing an accurate ICP. It is important to label the drainage system with the new reference points to ensure situational awareness among all members of the team on all shifts.If the drainage system includes negative drainage markings that coincide with the ordered drainage chamber level, the institution’s usual process for zeroing and obtaining an accurate ICP reading should be followed. For example, if the order directs the nurse to set the drip chamber at –5 cm of H2O below the FOM landmark and the drainage system allows for the drip chamber to be placed at this level, the original zero-reference point remains unchanged (Figure 1).When adjustment of the zero-reference point is necessary, it is important to independently consider the 2 functions of the EVD and its associated pressure transducer: CSF drainage and ICP monitoring. For appropriate CSF drainage, the chamber must be set at the ordered level; however, ICP readings will be inaccurate. To obtain an accurate ICP reading, the transducer must align with the FOM landmark and with the original zero-reference point on the drainage system.3,5 Before zeroing and obtaining an accurate ICP reading, the nurse must raise the drainage system to ensure this alignment. For example, if the drain has markings to –5 cm of H2O and the ordered drip chamber level is –10 cm of H2O, the zero-reference point must be adjusted during active draining. However, the transducer and true zero-reference point (0 cm of H2O) must be leveled with the FOM landmark when zeroing and obtaining an accurate ICP reading (Figure 2).Some drains do not have markings for negative drainage, but the nurse would follow a similar process as in the above example. In this case, +10 cm of H2O becomes the new zero-reference point and 0 cm of H2O becomes the new –10 cm of H2O. During active draining, the FOM landmark is leveled to +10 cm of H2O (new zero-reference point) and the drip chamber is set to 0 cm of H2O (the new –10 cm of H2O). When zeroing and obtaining an accurate ICP, the transducer and true zero-reference point (0 cm of H2O) must be leveled with the FOM landmark.External ventricular drains are commonly used for patients with various neurologic impairments, and at times negative-pressure drainage is required. Proper management of the drainage system and pressure transducer will reduce the risk of inaccurate ICP readings and ensure compliance with ordered drainage settings. Direct care nurses caring for patients with EVDs recognize that their 2 purposes, measuring ICP and draining CSF, may require changing the zero-reference point.
No takes yet. Share an insight, caveat, or question.
A 2024 study studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: