Key result
Cardiac safety factor formulation correlates linearly with charge needed to elicit propagating action potentials.
Why the study?
Solitonlike propagating modes have been proposed for excitable tissue but have never been measured in cardiac tissue.
Key points are not available for this paper at this time.
Design
Simulation study of a three-dimensional ventricular wedge preparation
Answers are grounded in this paper and cite their sources.
Solitonlike propagating modes have been proposed for excitable tissue, but have never been measured in cardiac tissue. In this study, we simulate an experimental protocol to elicit these propagating unstable wavelets (PUWs) in a detailed three-dimensional ventricular wedge preparation. PUWs appear as fixed-shape wavelets that propagate only in the direction of cardiac fibers, with conduction velocity approximately 40% slower than normal action potential excitation. We investigate their properties, demonstrating that PUWs are not true solitons. The range of stimuli for which PUWs were elicited was very narrow (several orders of magnitude lower than the stimulus strength itself), but increased with reduced sodium conductance and reduced coupling in nonlongitudinal directions. We show that the phenomenon does not depend on the particular membrane representation used or the shape of the stimulating electrode.
No takes yet. Share an insight, caveat, or question.
Boyle et al. (2012) studied this question. A quantitative mathematical formulation of the cardiac safety factor demonstrated a linear relationship with the actual charge required to elicit a propagating action potential in experimental and simulated models.
Synapse has enriched 10 related papers. Consider them for comparative context: