This paper describes a technique developed to make in situ, time-resolved measurements of the effective thermal conductivity of ash deposits formed under conditions that closely replicate those found in the convective pass of a commercial boiler. Since ash deposit thermal conductivity is thought to be strongly dependent on deposit microstructure, the technique is designed to minimize the disturbance of the natural deposit microstructure. Traditional techniques for measuring deposit thermal conductivity generally do not preserve the sample microstructure. Experiments are described that demonstrate the technique, quantify the experimental uncertainty, and determine the thermal conductivity of highly porous, unsintered deposits. The average measured thermal conductivity of loose, unsintered deposits is 0.14 ± 0.03 W m - 1 K - 1, approximately midway between rational theoretical limits for deposit thermal conductivity.