Key result
Patients with bicuspid aortic valves undergoing stentless aortic valve replacement had significantly better survival compared to those with tricuspid valves (HR 0.71; 95% CI 0.56-0.91; P=0.006).
Central MessageAnatomic and patient-specific variation exists between patients with bicuspid and tricuspid aortic valves, and these differences may impact durability of valve replacement choice.See Article page 177. In this issue of JTCVS Open, Brown and colleagues1Brown B. Le T. Naeem A. Malik A. Norton E.L. Wu X. et al.Stentless valves for bicuspid and tricuspid aortic valve disease.J Thorac Cardiovasc Surg Open. 2021; 8: 177-188Scopus (2) Google Scholar present a retrospective analysis of patients undergoing stentless aortic valve replacement for aortic stenosis and/or regurgitation in patients with bicuspid aortic valves (BAV) or tricuspid aortic valves (TAV). From 1992 to 2014, 1293 patients underwent stentless aortic valve replacement with modified inclusion technique at the University of Michigan and were followed for a median of 7.8 years (interquartile range, 4.2 years). The authors used propensity score matching to adjust for group differences and then performed Cox proportional hazard models and employed the Fine–Gray subdistribution method to compare survival and the cumulative incidence of reoperation due to structural valve deterioration with death as a competing risk. This is one of the largest single-institution series to date evaluating the aortic Freestyle prosthesis (Medtronic, Minneapolis, Minn) using the modified inclusion technique of implantation and the first to differentiate outcomes stratified by valve morphology. After matching, then multivariable adjustment, the authors reported that patients with BAV had better survival (hazard ratio, 0.71; 95% confidence interval [CI], 0.56-0.91, log-rank, P = .006) and similar hazard of reoperation over time (hazard ratio, 1.4; 95% CI, 0.8-2.6, log-rank P = .27). The authors also reported a greater incidence of reoperation in the patients with BAV at 15 years—15% (95% CI, 10%-22%) versus 11% (95% CI, 6.4%-17%) for patients with TAV (Gray test, P = .05). However, they chose to downplay the results of the cause-specific hazard model (above), which showed that after further adjustment for age, sex, and concomitant aortic surgery, there was no significant difference in hazard of reoperation over time between the 2 valve types. When interpreting the results of competing risk analyses, it is important to first understand what questions are being asked of the data. If one wants to simply estimate incidence for prognostic reasons, the Fine–Gray subdistribution method is appropriate; however, if one wants to delve deeper into addressing etiologic questions (such as the impact of BAV on need for reoperation when stentless valve is implanted), then cause-specific models should be sought out.2Austin P.C. Thomas N. Rubin D.B. Covariate-adjusted survival analyses in propensity-score matched samples: imputing potential time-to-event outcomes.Stat Methods Med Res. 2020; 29: 728-751Crossref Scopus (11) Google Scholar Fortunately, the authors have presented both for the reader. Regardless of how one interprets the findings of this report, it is important to note that anatomic and patient-specific variation exists between patients with BAV and TAV, and these differences may impact durability of valve replacement choice. Finally, 258 patients (20%) in this series of 1298 patients had incomplete reoperation follow-up data, perhaps limiting the reproducibility/generalizability of their conclusions. Furthermore, although the authors collected data on the reason for reoperation including valve dysfunction, valve infection, valve thrombosis, or other (such as aortic aneurysm and pseudoaneurysm), they only defined and reported reoperations for valve dysfunction from structural valve deterioration. Several other series with the modified inclusion technique have shown similar structural valve deterioration rates over time but have also included non-structural valve deterioration reoperations, which may be related to the bioprosthesis choice.3Bach D.S. Kon N.D. Long-term clinical outcomes 15 years after aortic valve replacement with the Freestyle stentless aortic bioprosthesis.Ann Thorac Surg. 2014; 97: 544-551Abstract Full Text Full Text PDF PubMed Scopus (50) Google Scholar, 4Mohammadi S. Tchana-Sato V. Kalavrouziotis D. Voisine P. Doyle D. Baillot R. et al.Long-term clinical and echocardiographic follow-up of the Freestyle stentless aortic bioprosthesis.Circulation. 2012; 126: S198-S204Crossref PubMed Scopus (44) Google Scholar, 5Amabile N. Bical O.M. Azmoun A. Ramadan R. Nottin R. Deleuze P.H. Long-term results of Freestyle stentless bioprosthesis in the aortic position: a single-center prospective cohort of 500 patients.J Thorac Cardiovasc Surg. 2014; 148: 1903-1911Abstract Full Text Full Text PDF PubMed Scopus (19) Google Scholar The group at University of Michigan has previously published on aortic valve reoperation for failed stentless bioprosthesis; interestingly, 75% of the patients in that cohort had BAV.6Yang B. Patel H.J. Norton E.L. Debenedictus C. Farhat L. Wu X. et al.Aortic valve reoperation after stentless bioprosthesis: short- and long-term outcomes.Ann Thorac Surg. 2018; 106: 521-525Abstract Full Text Full Text PDF PubMed Scopus (16) Google Scholar This is quite higher than the established prevalence of BAV during isolated aortic valve replacement ≈50%.7Roberts W.C. Ko J.M. Frequency of unicuspid, bicuspid and tricuspid aortic valves by decade in adults having aortic valve replacement for isolated aortic stenosis.Circulation. 2005; 111: 920-925Crossref PubMed Scopus (665) Google Scholar This was undoubtedly the impetus for the present analysis. Rather than comparing 2 distinct pathologic states (BAV vs TAV), it may be more practical for future study to address durability of stented versus stentless bioprostheses limited to patients with BAV to further help address the authors' hypothesis. Stentless valves for bicuspid and tricuspid aortic valve diseaseJTCVS OpenVol. 8PreviewTo determine long-term survival and reoperation rate in patients with a bicuspid aortic valve (BAV) and patients with a tricuspid aortic valve (TAV) after stentless aortic valve replacement (AVR)/aortic root replacement (ARR).
No takes yet. Share an insight, caveat, or question.
Wojnarski et al. (2021) conducted an editorial in Aortic stenosis and/or regurgitation (n=1,293). Bicuspid aortic valve (BAV) vs. Tricuspid aortic valve (TAV) was evaluated on Survival (HR 0.71, 95% CI 0.56-0.91, p=0.006). Patients with bicuspid aortic valves undergoing stentless aortic valve replacement had significantly better survival compared to those with tricuspid valves (HR 0.71; 95% CI 0.56-0.91; P=0.006).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: