Key result
Bicuspid anatomy yields similar early in-hospital adverse events to tricuspid anatomy after TAVI.
Why the study?
The bicuspid aortic valve poses technical challenges for TAVI due to altered valve geometry, asymmetric calcification, and larger annular dimensions, and early in-hospital outcomes compared to tricuspid valves are unclear.
Does transcatheter aortic valve implantation using contemporary self-expanding valves yield comparable early in-hospital adverse events in patients with bicuspid versus tricuspid aortic valve stenosis?
Cohort (n=60)
Yes
Does transcatheter aortic valve implantation using contemporary self-expanding valves yield comparable early in-hospital adverse events in patients with bicuspid versus tricuspid aortic valve stenosis?
Absolute Event Rate: 13.3% vs 8.9%
p-value: p=0.619
TAVI using contemporary self-expanding valves yielded statistically comparable early in-hospital safety outcomes in patients with bicuspid versus tricuspid aortic valve stenosis.
Supports TAVI feasibility with contemporary valves in bicuspid anatomy; extends observational data but leaves open need for randomized confirmation.
Background and Aim: Transcatheter aortic valve implantation (TAVI) is a well-established intervention for severe aortic stenosis (AS).The bicuspid aortic valve (BAV) continues to pose a technical challenge because of altered valve geometry, asymmetric calcification, and larger annular dimensions.Objectives to compare the early in-hospital clinical and procedural outcomes of TAVI in patients with bicuspid versus tricuspid aortic valve (TAV) stenosis using new-generation self-expanding Evolut R and Evolut PRO valves.We hypothesized that early in-hospital outcomes would be broadly comparable between the two groups despite the more complex bicuspid anatomy. Materials and Methods:This prospective observational cohort study enrolled 60 patients with significant symptomatic AS who underwent TAVI and were categorized by valve morphology into a BAV group (n=15) and a TAV group (n=45).Results: Diabetes mellitus was more prevalent in the TAV group than the BAV group (64.4% vs. 33.3%,P = 0.035; odds ratio 0.28, 95% confidence interval 0.08-0.95,favoring a lower prevalence in the BAV group).Annular dimensions, including the minimum, maximum, and mean annular diameters, the derived perimeter, and the annular area, were significantly larger in the BAV group (all P < 0.05).Post-procedural conduction abnormalities, complete heart block, atrial fibrillation, aortic regurgitation, and paravalvular leak did not differ significantly between groups.Mean and maximal pressure gradients after TAVI were significantly higher in the BAV group.Early adverse events were infrequent overall, with vascular complications and stroke occurring in 3.3% and 1.7% of the whole cohort, respectively, and did not differ significantly between groups.Conclusion: TAVI using contemporary self-expanding valves produced early in-hospital outcomes in BAV patients that were statistically comparable to those in TAV patients, despite significantly greater anatomical complexity, thereby supporting the feasibility of TAVI in carefully selected bicuspid patients.These early, hypothesis-generating findings from a two-center cohort warrant confirmation in larger, adequately powered, multicenter studies with longer follow-up.
No takes yet. Share an insight, caveat, or question.
Allam et al. (2026) conducted a cohort in Severe symptomatic aortic stenosis (n=60). Bicuspid aortic valve morphology vs. Tricuspid aortic valve morphology was evaluated on Early in-hospital permanent pacemaker implantation (p=0.619). In patients undergoing transcatheter aortic valve implantation, early in-hospital adverse events, including the need for permanent pacemaker implantation and paravalvular leak, did not differ significantly between bicuspid and tricuspid aortic valve anatomies.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: