Key result
Bicuspid TAVR shows comparable 1-year mortality to tricuspid anatomy.
Why the study?
Limited data are available on the use of self-expanding valves in patients with bicuspid aortic valve stenosis undergoing TAVR compared to tricuspid valves.
Cohort (n=27,086)
Yes
Absolute Event Rate: 10.4% vs 12.1%
p-value: p=0.63
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“This study suggests TAVR is a viable option for patients with bicuspid valve disease who are at increased surgical risk. It will be very important to continue to monitor these patients to see how the valves perform in 10 or 15 years.”
Registry study demonstrates comparable 1-year mortality and stroke rates between bicuspid and tricuspid aortic stenosis after transcatheter valve replacement, indicating acceptable safety.
OBJECTIVES This study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND TAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves. METHODS The Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up. RESULTS Between July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable. CONCLUSIONS All-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.
No takes yet. Share an insight, caveat, or question.
Forrest et al. (2020) conducted a cohort in Aortic valve stenosis (n=27,086). TAVR in bicuspid aortic valves vs. TAVR in tricuspid aortic valves was evaluated on All-cause mortality at 1 year (p=0.63). TAVR for bicuspid aortic valve stenosis showed comparable 1-year all-cause mortality to TAVR in tricuspid anatomy (10.4% vs 12.1%; P=0.63) in a propensity-matched registry analysis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: