Why the study?
Pulsed field ablation induces bubble nucleation and acoustic effects that may cause pressure-driven tissue damage, necessitating characterization and control of these effects.
Modifying PFA waveforms, such as using monophasic pulses, can minimize undesirable pressure waves and mechanical damage while maximizing the electroporation effect.
Monophasic pulses may reduce acoustic risks in PFA; hypothesis-generating for waveform optimization in clinical ablation.
Background Pulsed field ablation (PFA) is an emerging treatment option for arrhythmogenic myocardial tissue and solid tumors. PFA uses high voltage pulses to alter the electric potential across cell membranes, creating pores and eventual cell death. Bubble nucleation due to gas evolution at the electrode/electrolyte interface follows the delivery of current from the power generator to the body. Here, we investigate the acoustic effects induced by PFA to maximize the electroporation effect without pressure-driven damage. Methods Acoustic signals created by a PFA probe in saline were measured with a hydrophone. The lethality of PFA was tested in vitro in a 3D tissue mimic to resolve a ratio of cell death area to pressure. Mechanical damage created by PFA was then evaluated by gross measurements in agarose tissue mimics of different stiffness. Electrical resistance was tested with a plant-tissue model. Results Monophasic pulses create smaller pressure waves ( p < 0.05) and decrease the lethal threshold ( p < 0.05) compared to biphasic pulses. The length of the delay within a PFA pulse train has a significant effect on pressure ( p < 0.05) and insignificant effect on ablation areas (p = 0.9995 between 5 and 100 μs and p = 0.9997 between 50 and 100 μs). The cathode electrode creates more mechanical damage than the anode electrode ( p < 0.05). Conductivity as a function of electric field is more accurately described with a double sigmoid compared to a single sigmoid model (R 2 = 0.9898 vs 0.8772). Conclusions Bubble formation and void formation are generally undesirable when using PFA. This paper presents the first characterization of the pressure waves created by PFA and provides strategies for improving an electrical waveform to maximize the electroporation effect without violent acoustic waves.
No takes yet. Share an insight, caveat, or question.
Salameh et al. (2026) studied this question. Pulsed field ablation (PFA) waveforms (monophasic vs biphasic, delay lengths) vs. Alternative waveforms and electrode configurations was evaluated on Pressure waves and lethal threshold (cell death area to pressure ratio) (p=<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: