Key result
CNN accurately detects atrial fibrillation across diverse cohorts with AUCs exceeding ~0.95.
Why the study?
Most deep learning detectors for atrial fibrillation are validated on a single cohort and few report uncertainty, limiting generalizability assessment.
Observational
Yes
A compact convolutional neural network trained on a single ECG dataset can robustly and efficiently detect atrial fibrillation across multiple external validation cohorts, enabling broad generalization across different hospitals and recording hardware.
Multi-cohort validation achieved with one unchanged model; extends single-cohort AF detectors but leaves open clinical adoption.
Atrial fibrillation (AFib) is the most prevalent sustained cardiac arrhythmia, yet most deep learning detectors are validated on a single cohort and few report uncertainty. We developed a compact 14M-parameter convolutional neural network for binary AFib classification from 10 s, 12-lead ECG at 500 Hz, trained exclusively on the HDXML dataset (67,432 ECGs; 9628 AFib) with on-the-fly augmentation for noise, drift and missing channels. Using one unchanged checkpoint, we evaluated six independently sourced public cohorts totaling over 1.25 million recordings, including MIMIC-IV critical care and two ambulatory Holter cohorts. All metrics are reported with 95% confidence intervals from a cluster bootstrap at the patient, recording or subject levels. ROC–AUC exceeded 0.95 in every cohort, from 0.960 (95% CI 0.956–0.963) on CODE-15 to 0.999 (0.998–0.999) on SPH, including 0.966 (0.965–0.967) on MIMIC-IV with 75.3% sensitivity and 97.7% specificity, 0.963 (0.929–0.987) on CPSC 2021 and 0.995 (0.988–0.999) on MIT-BIH. Performance was stable under progressive lead masking without retraining, and median inference took 110 ms per segment on a server-class CPU without a GPU. A compact network trained on one curated source can therefore generalize across hospitals, countries and recording hardware. This study is retrospective; prospective validation is required before clinical use.
No takes yet. Share an insight, caveat, or question.
Mishra et al. (2026) conducted an observational in Atrial fibrillation. Convolutional neural network was evaluated on Detection of atrial fibrillation (ROC-AUC). A convolutional neural network for detecting atrial fibrillation generalized across six independent cohorts with ROC-AUCs exceeding 0.95, including 0.960 (95% CI 0.956-0.963) on CODE-15.