This is the authors' abstract. We don't add key points for this paper.
Wrist photoplethysmography (PPG) can support stress monitoring, and heart rate and interval variability are the simplest features it provides. I compared interval features with beat-shape and wavelet features on the public WESAD dataset (15 subjects; Empatica E4 blood volume pulse at 64 Hz; baseline versus the Trier Social Stress Test). Stage 1 used 620 quality-controlled 60 s windows (514 baseline, 106 stress; stress data from 11 subjects). Heart rate was the only feature with a significant paired change after Holm correction (+24.4 bpm, Holm p = 0.035), and dicrotic-notch features were unavailable in every stress window. Stage 2, an exploratory post hoc follow-up, re-timed beats at the maximum rate of rise, which lowered baseline RMSSD (root mean square of successive differences) from 113.0 to 64.1 ms, and added second-derivative features and within-subject z-scoring (602 windows; stress data from 9 subjects). Under leave-one-subject-out validation, interval-only feature sets reached a pooled area under the ROC curve (AUC) of 0.911 to 0.933 and all-feature sets 0.934 to 0.965 (Logistic Regression); all 95% intervals overlapped. The highest AUC, 0.972 with Random Forest, came from z-scoring, which uses the held-out subject’s unlabeled recording. The main limitation is the small number of stress subjects and windows.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Mahima Thapa (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: