Answers are grounded in this paper and cite their sources.
A normally quiet single-phase fan motor may become noisy when speed controlled using a conventional triac AC controller. The paper describes an investigation into the cause of this phenomenon. It is shown that the odd-time harmonic voltages introduced by the controller produce pulsating torques at all even multiples of the supply frequency, and that the extra noise components occur at these frequencies. A simple modification to the triac circuit is shown to reduce the effect, at the cost of increased power dissipation in the controller.
No takes yet. Share an insight, caveat, or question.
Williamson et al. (1981) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: