Background/Objectives: The Elecsys HCV Duo immunoassay simultaneously detects HCV core antigen (HCV Ag) and anti-HCV antibodies in a single sample. We evaluated its clinical performance against a standard-of-care reference algorithm of anti-HCV antibody and HCV RNA testing. Methods: We retrospectively analyzed 1332 residual serum or plasma samples tested with reference HCV RNA assays and the Alinity i Anti-HCV assay. Samples were classified as reference-positive, indicating current or past HCV infection (n = 166; 88 RNA+/Ab+ with active infection and 78 RNA−/Ab+ with resolved or treated infection), or reference-negative (n = 1166; RNA−/Ab−), including 1000 randomly selected blood donor samples. All specimens were tested with the Elecsys HCV Duo (cobas® e 801, Roche Diagnostics). Positive and negative percent agreements (PPA and NPA) were calculated against the combined reference standard. Results were further analyzed by infection status and viral load. No HCV RNA+/anti-HCV− (window-period) specimens were available. Results: Overall agreement was high (PPA 98.8% [164/166; 95% CI, 95.7–99.9%]; NPA 99.9% [1165/1166; 95% CI, 99.5–100.0%]). Agreement of the anti-HCV component with the Alinity i Anti-HCV assay was identical (PPA 98.8%, NPA 99.9%). The HCV Duo Ag component showed a PPA of 60.2% (95% CI, 49.2–70.5%) and NPA of 99.0% (95% CI, 98.3–99.5%) against HCV RNA detection. The Ag module was also reactive in 12 of 78 (15.4%) RNA−/Ab+ specimens, all from previously treated patients; thus, 53 of 65 (81.5%) dual Ag/Ab-reactive specimens had detectable HCV RNA. HCV Ag positivity was highest at HCV RNA ≥106 IU/mL (77.4%, 41/53), compared with 32.1% (9/28) at 104–106 IU/mL and 42.9% (3/7) at <104 IU/mL. Receiver operating characteristic analysis of the Ag component yielded an area under the curve of 0.920 (95% CI, 0.904–0.934). Conclusions: The Elecsys HCV Duo demonstrated high overall agreement with the reference methods, supporting its potential as a single-step screening test for HCV infection. Most, but not all, dual Ag/Ab-reactive specimens were viremic, so this result may help prioritize anti-HCV-positive individuals for linkage to care; however, the assay does not replace HCV RNA testing, which remains necessary to confirm active infection, particularly in Ag-negative or previously treated individuals. Because no window-period specimens were included, the potential of the assay for earlier detection of acute infection could not be evaluated.
No takes yet. Share an insight, caveat, or question.
Yoo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: