Answers are grounded in this paper and cite their sources.
A flexible low-frequency AC transmission system (LFTS) can extend the AC export range of offshore wind farms, but interactions among converter control loops may restrict its stable operating region. This paper develops a unified small-signal model comprising a grid-following wind farm, low-frequency cable, modular multilevel matrix converter (M3C), and receiving grid. A matrix-valued generalized Nyquist return ratio, together with modal participation and parameter-sensitivity analyses, indicates that the approximately 30 Hz dominant mode is strongly associated with the coupled control and network dynamics involving the phase-locked loop, wind-farm outer loops, M3C low-frequency voltage control, and transmission network. Based on bandwidth separation, a coordination strategy is proposed to move the critical control dynamics away from the interaction region. Comparisons between the state-space model and MATLAB/Simulink R2023b time-domain simulations show local agreement at the tested operating points. Power-step, weak-grid, bandwidth-sweep, and parameter-variation tests show that the proposed strategy, implemented solely through controller-parameter coordination without requiring additional hardware, suppresses oscillations, improves small-signal stability, and indicates a higher representative tested power-transfer boundary than PLL retuning at SCR = 1.50; 16 and 25 MW per turbine are the respective instability test points.
No takes yet. Share an insight, caveat, or question.
Lu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: