Key result
Presence of A2706G mtDNA polymorphism is linked to ~66% lower odds of sustained VT.
Why the study?
Mitochondrial DNA polymorphisms may contribute to arrhythmia risk, but their role in predicting sustained ventricular tachycardia in ICD candidates is unclear.
Do specific mitochondrial DNA polymorphisms (A2706G, G3010A, G9055A) from peripheral blood mononuclear cells predict the risk of sustained ventricular tachycardia in patients with ICD implantation indications?
Cross-Sectional (n=122)
Open-label
No
Do specific mitochondrial DNA polymorphisms (A2706G, G3010A, G9055A) from peripheral blood mononuclear cells predict the risk of sustained ventricular tachycardia in patients with ICD implantation indications?
Answers are grounded in this paper and cite their sources.
The absence of the A2706G mtDNA polymorphism, combined with advancing age and reduced eGFR, can aid in stratifying the risk of sustained ventricular tachycardia in patients eligible for an implantable cardioverter-defibrillator.
Background: Mitochondrial dysfunction in myocardium cells has been implicated in arrhythmogenesis, including ventricular tachycardia (VT). A carriage of point mitochondrial DNA (mtDNA) polymorphisms may contribute to the risk of certain arrhythmias. Therefore, it is hypothesized that mtDNA genotype could predict the risk of sustained VT (SVT). We aimed to explore whether specific mtDNA polymorphisms of peripheral blood mononuclear cells (PBMC) can serve as biomarkers for predicting the risk of SVT in patients with indications for an implantable cardioverter-defibrillator (ICD). Methods: A total of 122 patients with ICD implantation indications who underwent transthoracic echocardiography (TTE) were enrolled in the study. Total DNA from PBMC was isolated using the phenol-chloroform extraction method. Genotyping of mtDNA polymorphisms A2706G, G3010A and G9055A was performed using restriction fragment length polymorphism analysis. Correlations between clinical parameters and mtDNA polymorphisms with SVT registered prior to ICD implantation were evaluated. Based on our data, we developed a risk model for SVT. Results: Prior to ICD implantation, 70 (56.6%) patients had SVT (1st group) and 52 (43.4%) patients did not have SVT (2nd group). Patients with SVT were significantly older than patients without SVT (66.9 ± 9.9 year vs. 59.5 ± 10.6 year, p < 0.001), had a lower value estimated glomerular filtration rate (eGFR) (65.7 ± 19.7 mL/min/1.73 m2 vs. 77.9 ± 16.1 mL/min/1.73 m2, p < 0.001) and less frequently had A2706G mtDNA polymorphism (55.7% vs. 76.9%, p = 0.015). According to the multivariable logistic regression, age (odds ratio (OR) = 1.055, 95% confidence interval (CI) 1.009–1.103, p = 0.017), eGFR (OR = 0.974, 95% CI 0.949–0.999, p = 0.041) and absence of A2706G mtDNA polymorphism (OR = 0.335, 95% CI 0.141–0.797, p = 0.013) were independently associated with the SVT. We constructed a logistic equation with calculation of the cut-off value. The discriminative ability of the receiver operating characteristic curve (area under the curve) was 0.761 (95% confidence interval 0.675–0.833; sensitivity 65.71%; specificity 76.92%). Conclusions: In patients with ICD implantation indications, a carriage of mtDNA polymorphism A2706G is associated with SVT. Our risk model including age, eGFR and absence of A2706G mtDNA substitution was able to distinguish patients with SVT. Further investigations of their predictive significance are warranted. Clinical Trial Registration: NCT03667989 (https://clinicaltrials.gov/study/NCT03667989).
No takes yet. Share an insight, caveat, or question.
Atabekov et al. (2025) conducted a cross-sectional in Patients with implantable cardioverter-defibrillator indications (n=122). Absence of mtDNA A2706G polymorphism vs. Presence of mtDNA A2706G polymorphism was evaluated on Sustained ventricular tachycardia (SVT) registered prior to ICD implantation (OR 0.335, 95% CI 0.141-0.797, p=0.013). The absence of the A2706G mtDNA polymorphism was independently associated with sustained ventricular tachycardia in patients with indications for an implantable cardioverter-defibrillator.