Key result
Transcatheter mitral valve-in-band replacement achieves stable fixation and acutely resolves MR in swine.
Why the study?
Minimally invasive transcatheter mitral valve replacement after failed mitral valve repair with band annuloplasty remains largely unexplored due to concerns about lack of circumferential radial support.
Is transcatheter mitral valve-in-band (ViB) replacement feasible in a swine model of failed mitral repair?
Is transcatheter mitral valve-in-band (ViB) replacement feasible in a swine model of failed mitral repair?
This proof-of-concept large-animal study demonstrates the acute technical feasibility of transcatheter mitral valve replacement within a surgically implanted annuloplasty band.
May support ViB feasibility after annuloplasty in animals; leaves open clinical translation pending human trials.
Surgical mitral valve repair is the gold standard for severe primary mitral regurgitation (MR), yet when repairs fail, open reintervention carries substantial perioperative risk. Following band annuloplasty, minimally invasive options, such as transcatheter mitral valve replacement (TMVR), remain largely unexplored due to a hypothetical concern around the lack of circumferential radial support. Although transapical transcatheter mitral valve-in-band (ViB) replacement has been reported in a single human case, we report the first controlled large-animal model of ViB. A 68 kg, 20-month-old female Yucatan mini pig underwent placement of a 28 mm mitral annuloplasty band, oversized to create MR, via clamshell sternotomy under cardiopulmonary bypass; a simulated dilated left atrium enabled transcatheter access. A 23 mm Edwards SAPIEN 3 Ultra valve was deployed within the band using the Commander delivery system under fluoroscopic guidance. The valve achieved stable fixation without embolization, paravalvular leak (PVL), or left ventricular outflow tract (LVOT) obstruction with resolution of MR on echocardiography. The stable position was consistent with a contribution from the native anterior leaflet and annulus, although radial forces were not directly measured. The animal tolerated the procedure without complications. This first-in-animal study suggests the acute technical feasibility of TMVR within a mitral annuloplasty band and supports further investigation of percutaneous band modification strategies to optimize ViB outcomes.
No takes yet. Share an insight, caveat, or question.
Katter et al. (2026) studied Failed mitral repair / Mitral regurgitation (n=1). Transcatheter mitral valve-in-band replacement (23 mm Edwards SAPIEN 3 Ultra valve) was evaluated on Procedural feasibility, stable fixation, and resolution of mitral regurgitation. Transcatheter mitral valve-in-band replacement using a 23 mm Edwards SAPIEN 3 Ultra valve was acutely feasible in a swine model of failed mitral repair, achieving stable fixation and MR resolution.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: