The purpose of this work was to establish the suitability of micro-silica bead thermo-luminescent detectors, as dosimeters for I-125 low dose rate (LDR) brachytherapy measurements. Characteristics of the beads that are desirable for LDR dosimetry include their small size (1.1 mm thickness and 1.6 mm outer diameter) resulting in good spatial resolution, low cost, reusability, robust mechanical properties and inert chemical nature. Their torus geometry can also be beneficial for threading the beads in 2D and 3D unique arrangements, to fit anatomical shapes. Potential negative characteristics include relatively high effective atomic number compared to water. Method The following investigations were conducted: Linearity of thermo-luminescent response with dose; thermo-luminescent response of the Micro-Silica Beads to I-125 irradiation compared to calculated dose from TG43 formalism; consistency of readings within a batch; energy dependence of beads; accuracy of calibrating beads in a nominal 6 MV linac irradiation to determine dose under I-125 irradiation. Additionally, Monte Carlo simulations were used to investigate how the I-125 photon energy spectrum changes with distance from the source to determine the absorbed dose energy response of bead material relative to water. Results This study provides the first data on the use of micro-silica beads for dose measurements from I-125 sources. Linearity of bead response with dose has been demonstrated (R 2 = 0.999). Using a 6 MV calibration method, it was found that the beads measured to within −3.1% ( ± 10.7%, k = 2) and −5.7% ( ± 9.7%, k = 2) of the expected dose to water, for distances of 10 and 40 mm from the source respectively. All results fell within their estimated uncertainties. The Monte Carlo simulation work concluded that there is no distant dependent energy response, within distances of clinical relevance for brachytherapy; 5 to 40 mm from the source. Conclusion This study provides the first data on the use of MSBs for dose measurements from I-125 sources used in LDR prostate brachytherapy. A pragmatic approach to calibration of these dosimeters has been demonstrated utilising 6 MV from a linear accelerator, and measurement uncertainties for these dosimeters has been shown to be as good as other TLDs available commercially. The MSBs have an advantage over most other TLDs, for clinical use and for use in phantoms, because of their notably smaller dimensions, their toroid shape and hydrophobic composition.
No takes yet. Share an insight, caveat, or question.
Wilby et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: