Answers are grounded in this paper and cite their sources.
To the Editor: Isolation of the lungs with a cuffed endotracheal tube (ETT) has been recommended as an alternative to double-lumen tubes and bronchial blockers [1,2]. We report a situation in which this maneuver failed. A 17-yr-old, 33.0-kg girl with a lung abscess was scheduled for right thoracotomy. After routine induction of general anesthesia, her trachea was intubated with a 6.0-mm inner diameter cuffed ETT (Mallinckrodt Medical Inc., St. Louis, MO). A swivel adaptor was attached to the breathing circuit, and a 4-mm outerdiameter fiberoptic bronchoscope was passed down the ETT. The ETT cuff was deflated, and under fiberoptic guidance, the tube was advanced over the bronchoscope into the left main bronchus. The ETT cuff was reinflated. Auscultation revealed bilateral and equal breath sounds. Repeat bronchoscopic examination demonstrated the tip of the ETT in the bronchus just proximal to the orifice of the left upper lobe bronchus. During right thoracotomy, the right lung continued to be ventilated. The ETT was pulled back into the trachea, and a 5-French Fogarty embolectomy catheter was inserted alongside it. Under fiberoptic guidance, the catheter was advanced into the right main bronchus just below the carina. The catheter's balloon was inflated with 2.5 mL of air. The right lung collapsed and remained atelectactic throughout the procedure. The patient underwent right middle and right lower lobectomies. After the procedure, we used our patient's chest radiograph and computed tomographic scan to measure the length of her left main bronchus. It was <3.0 cm. The distance from the tip of the ETT to the inflated proximal border of its cuff was 4.5 cm. Therefore, despite bronchoscopic positioning, the inflated cuff of the ETT had not sealed the airway but had remained almost completely in the trachea, where it failed to separate the lungs (Figure 1). If the ETT had been advanced until its cuff was far enough into the bronchus to seal the airway, its tip would have extended past the upper lobe, compromising ventilation to that lobe (Figure 2).Figure 1: Under bronchoscopic guidance, the endotracheal tube was advanced down the left main bronchus until its tip was positioned just proximal to the orifice of the left-upper lobe. In this position, the inflated cuff remained almost completely above the carina, and both lungs remained ventilated during surgery.Figure 2: If the endotracheal tube had been advanced so that its cuff was entirely in the left main bronchus, ventilation to the left upper lobe would have been obstructed by the body of the tube.Advancing an uncut cuffed ETT into the bronchus is recommended in emergency situations or when other lung separation techniques fail. If this technique is used, one must consider the size of the patient's airway and the dimensions of the tube chosen. Failure to isolate the lungs can still occur despite bronchoscopic confirmation of what appears to be correct tube placement. Cathy R. Lammers, MD* Gregory B. Hammer, MD* Jay B. Brodsky, MD* Walter B.
No takes yet. Share an insight, caveat, or question.
Lammers et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: