Key result
1-2-3-LQTS-Risk model predicts life-threatening arrhythmias with a C-index of ~0.69 in external validation.
Why the study?
Risk stratification of patients with long QT syndrome is challenging, and external validation of a novel 5-year risk prediction model was needed.
Cohort (n=1,689)
Answers are grounded in this paper and cite their sources.
May inform ICD decisions in LQTS; leaves open prospective validation before changing practice.
AIMS: Risk stratification of patients with long QT syndrome (LQTS) represents a difficult task. In 2018, we proposed a granular estimate of the baseline 5-year risk of life-threatening arrhythmias (LAE) for patients with LQTS, based on the genotype (long QT syndrome Type 1, long QT syndrome Type 2, and long QT syndrome Type 3) and the duration of the QTc interval. We sought to externally validate a novel risk score model (1-2-3-LQTS-Risk model) in a geographically diverse cohort from the USA and to evaluate its performance and assess potential clinical implication of this novel model. METHODS AND RESULTS: The prognostic model (1-2-3-LQTS-Risk model) was derived using data from a prospective, single-centre longitudinal cohort study published in 2018 (discovery cohort) and was validated using an independent cohort of 1689 patients enrolled in the International LQTS Registry (Rochester NY, USA). The validation study revealed a C-index of 0.69 [95% confidence interval (CI): 0.61-0.77] in the validation cohort, when compared with C-index of 0.79 (95% CI: 0.70-0.88) in the discovery cohort. Adopting a 5-year risk ≥5%, as suggested by the ROC curve analysis as the most balanced threshold for implantable cardioverter-defibrillator (ICD) implantation, would result in a number needed to treat (NNT) of nine (NNT = 9; 95% CI: 6.3-13.6). CONCLUSION: The 1-2-3-LQTS-Risk model, the first validated 5-year risk score model for patients with LQTS, can be used to aid clinicians to identify patients at the highest risk of LAE who could benefit most from an ICD implant and avoid unnecessary implants.
No takes yet. Share an insight, caveat, or question.
Mazzanti et al. (2021) conducted a cohort in Long QT syndrome (LQTS) (n=1,689). 1-2-3-LQTS-Risk model vs. Discovery cohort was evaluated on Model discrimination (C-index) for 5-year risk of life-threatening arrhythmias (C-index 0.69, 95% CI 0.61-0.77). The 1-2-3-LQTS-Risk model demonstrated a C-index of 0.69 in external validation, where a 5-year risk threshold of ≥5% for ICD implantation yielded a number needed to treat of 9.
Synapse has enriched 10 related papers. Consider them for comparative context: