Key result
Minimally invasive AVR via hemisternotomy is linked to ~95% lower odds of in-hospital stroke or TIA.
Why the study?
Whether minimally invasive aortic valve replacement reduces perioperative stroke risk compared to conventional sternotomy remains uncertain.
Does minimally invasive aortic valve replacement via upper hemisternotomy reduce the incidence of perioperative in-hospital stroke or transient ischemic attack compared with conventional full median sternotomy in adults undergoing elective, isolated aortic valve replacement?
Cohort (n=310)
No
Does minimally invasive aortic valve replacement via upper hemisternotomy reduce the incidence of perioperative in-hospital stroke or transient ischemic attack compared with conventional full median sternotomy in adults undergoing elective, isolated aortic valve replacement?
In a propensity-matched cohort of elective isolated AVR patients, minimally invasive upper hemisternotomy was associated with zero perioperative strokes/TIAs compared to 4.5% with full sternotomy, supporting its neurological safety in experienced centers.
Answers are grounded in this paper and cite their sources.
miniAVR was associated with lower perioperative stroke/TIA in matched AVR; hypothesis-generating and requires randomized confirmation before practice change.
Background/Objectives: Stroke is a devastating complication after aortic valve replacement (AVR). Whether minimally invasive AVR (miniAVR) reduces perioperative stroke risk versus conventional sternotomy remains uncertain. Methods: This single-center retrospective cohort study used propensity score matching (PSM) in 1741 consecutive patients undergoing isolated AVR (2014–2025). After exclusions, 1:1 PSM using 10 covariates created 155 matched pairs with excellent balance (all standardized mean differences < 0.20). The primary endpoint was in-hospital stroke or transient ischemic attack (TIA); secondary endpoints were 30-day and 5-year mortality and major complications. Firth penalized logistic regression identified independent predictors of stroke/TIA. Results: Stroke/TIA occurred in 0/155 (0.0%) miniAVR versus 7/155 (4.5%) conventional patients (p = 0.015); the rule-of-three upper 95% limit for miniAVR was ~1.9%. Thirty-day mortality was similar (0.6% vs. 2.6%; p = 0.371). Five-year survival favored miniAVR (94.6% vs. 87.2%; log-rank p = 0.047). miniAVR was independently associated with lower stroke/TIA odds (odds ratio [OR] 0.052; 95% confidence interval [CI] 0.003–0.832; p = 0.037); longer cardiopulmonary bypass time was associated with higher odds (OR 1.014/minute; 95% CI 1.001–1.028; p = 0.032). Conclusions: miniAVR was associated with zero observed perioperative strokes and higher 5-year survival; however, this survival comparison is limited by short median follow-up in the miniAVR group (1.9 years). Given the small number of events and the single-center design, these findings should not be interpreted as proof of a causal neuroprotective effect. Multicenter validation with longer, balanced follow-up is required.
No takes yet. Share an insight, caveat, or question.
Kowalówka et al. (2026) conducted a cohort in Predominant aortic stenosis or regurgitation requiring surgical aortic valve replacement (n=310). Minimally invasive aortic valve replacement via upper hemisternotomy (miniAVR) vs. Conventional aortic valve replacement via full median sternotomy was evaluated on Composite of in-hospital ischemic stroke or transient ischemic attack (TIA) (OR 0.052, 95% CI 0.003-0.832, p=0.037). Minimally invasive AVR via upper hemisternotomy was associated with lower in-hospital stroke or TIA compared to conventional full sternotomy.
Synapse has enriched 10 related papers. Consider them for comparative context: