This study experimentally compares an uncooled photovoltaic (PV) panel with two low‐cost evaporative cooling configurations under identical outdoor conditions in Nagpur, India. A system comprises a pump assisted honeycomb‐pad evaporative cooling system (PV‐HCEC) and a passive earthen pot evaporative water‐cooling system (PV‐EPEWC). PV‐HCEC was tested at water flow rates of 1, 3, and 5 LPM, whereas PV‐EPEWC operated through natural thermosyphon circulation. The reference panel reached maximum internal and front surface temperatures of 63 and 68°C, respectively. At 5 LPM, PV‐HCEC reduced these temperatures to 49 and 47°C, while PV‐EPEWC reduced them to 54 and 52°C. The maximum electrical efficiency increased from 10.71% for the reference panel to 18.06% for PV‐HCEC and 16.01% for PV‐EPEWC. The maximum thermal and overall efficiencies were 69.65% and 82.89% for PV‐HCEC and 62.97% and 75.80% for PV‐EPEWC, respectively. PV‐HCEC achieved an electricity cost of 5.44 INR kWh −1 , an annualized LCOE of 7.06 INR kWh −1 , a simple payback period of 6.258 years, an energy payback time of 1.52 years, and net CO 2 mitigation of 6.16 t year −1 . The results demonstrate that PV‐HCEC provides stronger thermal and techno‐economic performance, whereas PV‐EPEWC offers a simpler pump‐free option for decentralized and resource‐constrained applications.