Answers are grounded in this paper and cite their sources.
Purpose: To compare efficacy, safety and stability of Femtosecond assisted LASIK andimplantable collamer lens implantation in correction of high myopia. Methods: This study was nonrandomized comparative prospective consecutive interventional study. It included 74 eyes withhigh myopia (≥ -6 Ds) of 40 patients attended to the outpatient ophthalmic clinic of Sohaguniversity hospitals from the period from Jan.2016 to Jan.2017. The patients were divided intotwo groups depending on: Degree of myopia, corneal thickness and corneal tomography. Thefirst group (34 eyes) of 20 patients were subjected to implantable collamer lensesimplantation and the second group (40 eyes) of 40 patients were subjected to femtosecondassisted LASIK. Results: Group one (ICL group) showed UCVA preoperative was (1.90±0.29)and UCVA postoperative was (0.27±0.21) with (p-value<0.000*). BCVA preoperative was(0.526±0.272) and that of BCVA postoperative was (0.217±0.128) with (p-value<0.001*), whichmeans that BCVA postoperative was better than what was expected from the BCVA preoperative. Spherical error decreased from (-13.576±3.945) preoperative to (-0.0385±0.821) postoperative with (p-value<0.000*).Cylindrical error preoperative was (-1.134±0.617) and postoperative was (-0.352±0.250) with (p-value<0.000*).Spherical equivalent preoperative was (-15.173±4.079) and that of postoperative was (-0.269±0.787) with (p-value<0.000*). Pachymetry preoperative was (518.153±22.981) and postoperative was (521± 22.304) with (p-value <0.140).Group two (Femtosecond assisted LASIK) UCVA preoperative was (1.42±0.27) and UCVApostoperative was (0.366±0.21) with (p-value<0.000*).There wasnít significant difference betweenBCVA preoperative and postoperative. Spherical error preoperative was (-8.398±1.733) and postoperative (-0.796±1.186) with (p-value<0.000*). Cylinder error mean value preoperative was (-1.648±0.838) corrected to (-0.765±0.423) with (p-value< 0.005). Spherical equivalent preoperative was (-9.213±1.899) and that of postoperative is (-0.935±1.11) with (p-value<0.000*).Pachymetry preoperative was (535.111±26.33) and postoperative (419.88± 43.063) with (pvalue<0.000*). Conclusion: Both implantable collamer lens and Femtosecond assistedLASIK proved high efficacy and safety but implantable collamer lens showed more stability forhigh myopic patients.
No takes yet. Share an insight, caveat, or question.
Abdelmateen et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: