Answers are grounded in this paper and cite their sources.
This paper develops a position self-sensing approach for a motion actuator based on a dielectric elastomer membrane. The proposed method uses voltage and current measurements to estimate the electrical resistance and capacitance online by means of a high-frequency low-amplitude voltage component injected in the actuation signal. The actual deformation is subsequently reconstructed using a model-based estimate of the electrical parameters implemented on a field programmable gate array platform (FPGA) with a sampling frequency of 20 kHz. The main peculiarity of the approach is the use of recursive identification and filtering algorithms that avoid the need of charge measurements. The self-sensing algorithm is extensively validated on a precision linear-motion actuator, which uses a nonlinear biasing system to obtain large actuation strokes.
No takes yet. Share an insight, caveat, or question.
Rizzello et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: