Key result
Tenzing 7 delivery catheter boosts aspiration catheter delivery success to in vitro.
Why the study?
In large vessel occlusion stroke, navigation of aspiration catheters can be impeded by vessel tortuosity and the ophthalmic artery origin, motivating evaluation of a novel tapered delivery catheter designed to facilitate delivery without disturbing the embolus.
Does the Tenzing 7 delivery catheter improve the deliverability and speed of large-bore aspiration catheters to the middle cerebral artery without crossing the occlusion compared with standard microcatheter and microwire combinations?
Does the Tenzing 7 delivery catheter improve the deliverability and speed of large-bore aspiration catheters to the middle cerebral artery without crossing the occlusion compared with standard microcatheter and microwire combinations?
Answers are grounded in this paper and cite their sources.
The tapered Tenzing 7 delivery catheter overcomes the ophthalmic artery ledge effect to markedly improve rapid, clot-sparing delivery of large-bore aspiration catheters in both tortuous in vitro vascular models and initial clinical stroke thrombectomy practice.
BACKGROUND: In large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience. METHODS: In a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7. RESULTS: In vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%). CONCLUSION: Compared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model's observations.
No takes yet. Share an insight, caveat, or question.
Frölich et al. (2020) studied Acute ischemic stroke with intracranial large vessel occlusion (n=154). Tenzing 7 (T7) Delivery Catheter vs. Standard microcatheter (Headway 21 or 3MAX) and 0.014-inch microwire combinations was evaluated on In vitro aspiration catheter delivery success rate to the proximal M1 segment of the middle cerebral artery (p=<0.001). The Tenzing 7 delivery catheter increased in vitro aspiration catheter delivery success and speed compared to standard microcatheters.