Key result
Weight-based aortic valve formula mildly underestimates echocardiographic diameter by ~0.1 cm.
Why the study?
A formula to predict echocardiographic aortic valve diameter based on body weight was needed to improve echo-hemodynamic evaluations in dogs.
Does a body weight-based formula accurately predict echocardiographic aortic valve diameter and stroke volume in dogs?
Observational (n=176)
Does a body weight-based formula accurately predict echocardiographic aortic valve diameter and stroke volume in dogs?
A body weight-based formula for calculating canine aortic valve diameter shows high correlation but causes mild underestimations that affect stroke volume calculations.
Answers are grounded in this paper and cite their sources.
May aid AV diameter prediction in stable dogs; leaves open need for prospective validation before hemodynamic use.
Objective: To generate and test a formula to predict the echocardiographic aortic valve (AV) diameter (AVd) for use in echo-hemodynamic evaluations. Methods: Echocardiograms of hemodynamically stable dogs more than 1 year old that included images of the AV in the right parasternal inflow-outflow view with concurrent ECG were included. Exclusions included AV pathology, congestive heart failure, systolic dysfunction, sustained arrhythmias, congenital heart diseases, hypovolemia, systemic hypertension, and pericardial and pleural space diseases. The AVd was measured in centimeters in triplicate using digital calipers. A linear regression examined the relationship between weight and AVd, generating a predictive formula. Next, 20 dogs had their AVd measured and predicted, and stroke volumes were calculated using each method. These were compared using the paired Student t test, intraclass correlation coefficients, coefficients of variation, and Bland-Altman plots. Results: Data from 176 unique dogs included 64 (34.7%) normal hearts and 109 (61.9%) with preclinical myxomatous mitral and/or tricuspid valve disease. The median (range) age was 8 (1 to 16) years; weight was 9.6 (1.7 to 73) kg. The median (range) AVd was 1.20 (0.60 to 2.45) cm. The formula derived was AVd = 0.545 X (weight)0.347 (r2 = 0.875). Despite moderate agreement and low variation between the predicted and measured AVd, differences occurred due to mild systematic underestimation (-0.1 ± 0.13 cm), with consequent underestimation of stroke volumes. Conclusions: The formula allowed calculation of AVd, although underestimation resulted in differences between measured and predicted stroke volumes. Clinical Relevance: Using a formula can reduce acquisition and measurement error; however, it must be validated with a larger sample.
No takes yet. Share an insight, caveat, or question.
Kennedy et al. (2025) conducted an observational in Hemodynamically stable dogs (normal or preclinical valve disease) (n=176). Body weight-based predictive formula for aortic valve diameter vs. Direct echocardiographic measurement was evaluated on Predictive accuracy of the AVd formula and stroke volume agreement (r2 = 0.875). A derived body weight-based formula for predicting aortic valve diameter resulted in mild systematic underestimation compared to direct echocardiographic measurement.