Key result
The introduction of a novel technology-enabled cardiac rehabilitation service model increased patient entry into the program from 76.0% to 84.3% and improved completion rates from 47.4% to 75.6%.
Why the study?
Buckinghamshire Healthcare NHS Trust redesigned its cardiac rehabilitation service to optimize patient recruitment, retention, and reduce readmissions.
Observational (n=700)
No
Answers are grounded in this paper and cite their sources.
May enhance cardiac rehab uptake in retrospective data; hypothesis-generating and requires prospective validation before practice change.
BACKGROUND: Buckinghamshire Healthcare NHS Trust (BHT) carried out a cardiac rehabilitation (CR) service redesign aimed at optimising patient recruitment and retention and decreasing readmissions. METHODS: A single centre observational study and local service evaluation were carried out to describe the impact of the novel technology-enabled CR model. Data were collected for adult patients referred for CR at BHT, retrospectively for patients referred during the 12-month pre-implementation period (Cohort 1) and prospectively for patients referred during the 12-month post-implementation period (Cohort 2). The observational study included 350 patients in each cohort, seasonally matched; the service evaluation included all eligible patients. No data imputation was performed. RESULTS: In the observational study, a higher proportion of referred patients entered CR in Cohort 2 (84.3%) than Cohort 1 (76.0%, P = 0.006). Fewer patients in Cohort 2 had ≥1 cardiac-related emergency readmission within 6 months of discharge (4.3%) than Cohort 1 (8.9%, P = 0.015); readmissions within 30 days and 12 months were not significantly different. Median time to CR entry from discharge was significantly shorter in Cohort 2 (35.0 days) than Cohort 1 (46.0 days, P < 0.001). The CR completion rate was significantly higher in Cohort 2 (75.6%) than Cohort 1 (47.4%, P < 0.001); median CR duration for completing patients was significantly longer in Cohort 2 (80.0 days) than Cohort 1 (49.0 days, P < 0.001). Overall, similar results were observed in the service evaluation. CONCLUSIONS: Introduction of the novel technology-enabled CR model was associated with short-term improvements in emergency readmissions and sustained increases in CR entry, duration and completion.
No takes yet. Share an insight, caveat, or question.
McCartan et al. (2017) conducted an observational in Coronary heart disease (n=700). Novel technology-enabled cardiac rehabilitation service model vs. Pre-implementation cardiac rehabilitation service model was evaluated on Cardiac rehabilitation entry rate (p=0.006). The introduction of a novel technology-enabled cardiac rehabilitation service model increased patient entry into the program from 76.0% to 84.3% and improved completion rates from 47.4% to 75.6%.
Synapse has enriched 10 related papers. Consider them for comparative context: