Key result
ABPM demonstrates greater short-term stability than unattended automated office BP, regardless of HIV status.
Why the study?
Blood pressure measurement in sub‐Saharan Africa often relies on single‐day, conventional office readings prone to measurement error, and the reproducibility of unattended automated office BP and ambulatory BP monitoring by HIV status was unclear.
Does the short-term reproducibility of uAOBP and ABPM differ by HIV status in a Tanzanian cohort?
Cohort (n=750)
Does the short-term reproducibility of uAOBP and ABPM differ by HIV status in a Tanzanian cohort?
Mean Difference: -1.02 (95% CI -1.76–-0.27)
Both ABPM and uAOBP demonstrated high short-term reproducibility regardless of HIV status, supporting their use for blood pressure assessment in sub-Saharan Africa.
Sub‐Saharan Africa (sSA) bears a high burden of hypertension and HIV, yet blood pressure measurement often relies on single‐day, conventional office readings, prone to measurement error. We assessed the short‐term repeatability of unattended, automated office BP (uAOBP) and ambulatory blood pressure monitoring (ABPM), and whether reproducibility differs by HIV status in Tanzania. We analyzed data from the Mwanza HIV&CVD cohort study, using measurements from enrollment and 1‐month later. Bland‐Altman plots visualized mean differences and limits of agreement. Reproducibility of hypertension classification was calculated using Cohen's kappa, with differences by HIV status evaluated using large‐sample variance. Of 999 participants enrolled, 750 (384 people with HIV (PWH) and 366 people without HIV (PWoH)) had valid ABPM measurements at both timepoints. The mean difference in systolic blood pressure was significant for uAOBP (−1.02 mmHg; 95% CI −1.76, −0.27) but not 24 h ABPM (−0.46; −1.02, 0.10), with similar results for diastolic blood pressure. Bland‐Altman plots showed narrower limits of agreement for ABPM. Kappa statistics were 0.45 (0.33, 0.56) for uAOBP and 0.56 (0.50, 0.62) for 24 h ABPM. Regression dilution ratios were 0.77 and 0.82 for systolic and diastolic uAOBP and 0.73 and 0.77 for ABPM. Reproducibility did not differ by HIV status. ABPM and uAOBP demonstrated high short‐term reproducibility, with ABPM showing greater stability for hypertension classification. Reproducibility did not differ by HIV status, supporting the use of both approaches in sub‐Saharan Africa.
No takes yet. Share an insight, caveat, or question.
Willkens et al. (2026) conducted a cohort in Hypertension and HIV (n=750). Unattended automated office BP (uAOBP) and ambulatory blood pressure monitoring (ABPM) was evaluated on Mean difference in systolic blood pressure between enrollment and 1-month follow-up for uAOBP (MD -1.02 mmHg, 95% CI -1.76 to -0.27). Ambulatory blood pressure monitoring showed greater short-term stability than unattended automated office BP (mean difference -0.46 vs -1.02 mmHg), with no reproducibility differences by HIV status.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: