Key result
Prosthetic valve dysfunction shows heterogeneous etiologies, led by haemolysis in ~36% of cases.
Why the study?
Prosthetic valve dysfunction is a clinically important complication requiring comprehensive evaluation of clinical presentation, valve haemodynamics, and underlying mechanisms.
Observational (n=77)
No
Prosthetic valve dysfunction presents with heterogeneous clinical and etiological features, commonly including haemolysis and thrombosis, underscoring the need for integrated echocardiographic and complementary imaging assessment.
May inform differential diagnosis and imaging strategies in prosthetic valve dysfunction; hypothesis-generating single-center data requiring prospective multicenter validation.
Background: Prosthetic valve dysfunction is a clinically important complication of valve replacement, with potentially serious haemodynamic, thromboembolic and infectious consequences. Its assessment requires evaluation of the clinical presentation, prosthetic valve haemodynamics and underlying mechanisms. Objective: To describe the clinical, echocardiographic and aetiological characteristics of patients with prosthetic valve dysfunction managed at Mohammed VI University Hospital Centre, Marrakech. Methods: This retrospective, observational, single-centre study included 77 patients with suspected or confirmed prosthetic valve dysfunction. Clinical characteristics, echocardiographic findings, cinefluoroscopic assessments and aetiological investigations were reviewed using the available hospital records. Results: The mean patient age was 54.1 ± 13.6 years, and 53.2% were women. Most patients were symptomatic, with 62.3% classified as New York Heart Association functional class III–IV. Ischaemic neurological events were documented in 26.0% of patients, while respiratory instability occurred in 14.3%. Transthoracic echocardiography demonstrated satisfactory prosthetic valve opening in 48 patients (62.3%). Left ventricular systolic dysfunction was identified in 23 patients, including eight with severe dysfunction. The mean systolic pulmonary artery pressure was 38.3 ± 10.9 mmHg. Haemolysis was identified in 28 patients (36.4%), prosthetic valve thrombosis in 17 (22.1%), pannus formation in 15 (19.5%) and infective endocarditis in nine (11.7%). Several mechanisms coexisted or remained difficult to differentiate. Conclusion: Prosthetic valve dysfunction demonstrated heterogeneous clinical and aetiological characteristics. An integrated assessment using echocardiography and complementary imaging was important for identifying the underlying mechanisms and informing clinical management.
No takes yet. Share an insight, caveat, or question.
Haffane et al. (2026) conducted an observational in Prosthetic valve dysfunction (n=77). Prosthetic valve dysfunction was evaluated on Clinical, echocardiographic, and aetiological characteristics. Prosthetic valve dysfunction presented with heterogeneous aetiologies, including haemolysis in 36.4%, prosthetic valve thrombosis in 22.1%, and pannus formation in 19.5% of cases.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: