Answers are grounded in this paper and cite their sources.
We present a benchtop Faraday wave dispersion method for measuring the interfacial tension of room-temperature liquid metals. A GaInSn layer covered by NaOH solution is vertically vibrated (30–70 Hz) to excite subharmonic standing waves at the GaInSn–NaOH electrochemical interface. Wavelengths are extracted from time-averaged images via zero-padded spatial FFT (2048 px) with a meniscus-excluding mask. A nonlinear least-squares fit of the two-layer dispersion relation over seven frequencies and 41 individual measurements yields σ = 0.488 N/m (R2 = 0.990). Including all experimental uncertainty sources, the final result is σ = 0.488 ± 0.027 N/m. Independent pendant-drop measurements on the same GaInSn–NaOH interface give σ = 0.444 N/m, consistent with published pendant-drop and microfluidic tensiometry values spanning 0.40–0.50 N/m. The method requires no transmission through the working fluid, making it suitable for opaque liquid metals where conventional optical tensiometry is precluded.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: