Key result
MCE improves CAD diagnostic accuracy by ~10 points over wall motion analysis during DSE.
Why the study?
The relative merits of myocardial contrast echocardiography and wall motion analysis for detecting coronary artery disease during dobutamine stress echocardiography have not been studied in a large patient cohort.
Does myocardial contrast echocardiography improve diagnostic accuracy for coronary artery disease compared to wall motion analysis during dobutamine stress echocardiography?
Cross-Sectional (n=170)
Does myocardial contrast echocardiography improve diagnostic accuracy for coronary artery disease compared to wall motion analysis during dobutamine stress echocardiography?
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“Consistent with previous studies, we demonstrated that the analysis of myocardial perfusion increased the sensitivity and diagnostic accuracy of dobutamine stress echocardiography for detecting angiographically significant coronary artery disease. Thus, our findings demonstrate the potential use of real-time myocardial contrast echocardiography as an alternative and safe method of perfusion imaging during stress testing.”
Myocardial contrast echocardiography significantly improves the sensitivity and overall accuracy of dobutamine stress echocardiography for detecting coronary artery disease compared to standard wall motion analysis.
OBJECTIVE: This study sought to compare the accuracy of myocardial contrast echocardiography (MCE) and wall motion analysis (WMA) during submaximal and peak dobutamine stress echocardiography (DSE) for the diagnosis of coronary artery disease (CAD). BACKGROUND: The relative merits of MCE and WMA for the detection of CAD during DSE have not been studied in a large number of patients. METHODS: We studied 170 patients who underwent dobutamine (up to 50 microg/kg/min)-atropine stress testing and coronary angiography. The WMA and MCE (using repeated boluses of Optison [Mallinckrodt, St. Louis, Missouri] or Definity [Bristol-Myers Squibb, New York, New York]) were performed at rest, at intermediate stress (65% to 75% of maximal heart rate), and at peak stress. The diagnosis of CAD (>/=50% stenosis in >/=1 coronary artery) was based on reversible wall motion and perfusion abnormalities. RESULTS: Coronary artery disease was detected in 127 (75%) patients. Sensitivity of MCE was higher than that of WMA at maximal stress (91% vs. 70%; p = 0.001) and at intermediate stress (84% vs. 20%; p = 0.0001). Specificity was lower for MCE compared with WMA (51% vs. 74%; p = 0.01). Overall accuracy was higher for MCE than for WMA (81% vs. 71%; p = 0.01). Sensitivity for detection of CAD based on abnormalities in >/=2 vascular regions was higher for MCE than for WMA (67% vs. 28%; p < 0.01). CONCLUSIONS: The majority of inducible perfusion abnormalities occur at an intermediate phase of the stress test, without wall motion abnormalities. Myocardial contrast echocardiography provides better sensitivity than WMA, particularly in patients with submaximal stress and in identifying patients with multivessel CAD.
No takes yet. Share an insight, caveat, or question.
Elhendy et al. (2004) conducted a cross-sectional in Coronary artery disease (n=170). Myocardial contrast echocardiography vs. Wall motion analysis was evaluated on Overall accuracy for the diagnosis of coronary artery disease (≥50% stenosis in ≥1 coronary artery) (p=0.01). Myocardial contrast echocardiography had higher overall accuracy than wall motion analysis for diagnosing coronary artery disease during dobutamine stress echocardiography (81% vs. 71%; p=0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: