Key result
Power-Doppler MCE had 94% accuracy for identifying stenotic coronary arteries, which was similar to SPECT (94%) and higher than echo wall-motion analysis (83%).
Why the study?
Does power-Doppler MCE compare favorably to SPECT and echo wall-motion analysis for detecting coronary artery stenosis in patients undergoing pharmacological stress testing?
Cross-Sectional (n=25)
Does power-Doppler MCE compare favorably to SPECT and echo wall-motion analysis for detecting coronary artery stenosis in patients undergoing pharmacological stress testing?
Power-Doppler MCE is a highly specific and sensitive method for detecting myocardial perfusion defects during pharmacological stress, with accuracy comparable to SPECT and slightly higher than stress-echo wall-motion analysis.
Power-Doppler MCE merits prospective validation versus SPECT; should not yet change diagnostic algorithms for coronary stenosis.
BACKGROUND: Power-Doppler imaging is a recently developed method for myocardial contrast echocardiography (MCE). It can selectively evaluate the signal coming from an ultrasound contrast agent, allowing myocardial perfusion studies. OBJECTIVE: To compare the ability of power-Doppler MCE with stress-echo wall-motion and nuclear scan imaging (SPECT) to assess myocardial ischaemia during pharmacological stress, using coronary angiography as reference. METHODS: In 25 patients the three non-invasive imaging modalities were acquired during a single dipyridamole stress test (so as to avoid stress variations). Power-Doppler MCE was acquired using continuous intravenous infusion of Levovist. Echo wall-motion was acquired too. At peak stress 99Tc-Sestamibi was injected; stress SPECT images were acquired 30 min after injection. RESULTS: Power-Doppler MCE and SPECT showed 84% concordance (21 of 25 patients; kappa=0.67) for detection of ischaemia. Concordance based on coronary artery territories for normal perfusion versus fixed defects versus reversible defects was 92% (69 of 75; kappa=0.81), with 100% for left anterior descending, 92% for right coronary artery and 84% for circumflex. Power-Doppler MCE had lower sensitivity than SPECT (89 versus 100%) but higher specificity (100 versus 88%) for identification of stenotic (> or = 70%) coronary arteries as assessed by angiography. Echo wall-motion analysis showed the lowest sensitivity (68%) with 100% specificity. Accuracy was 94% for both power-Doppler MCE and SPECT, and 83% for wall-motion analysis. CONCLUSION: Power-Doppler MCE is a sensitive and specific method for identification of myocardial perfusion during pharmacological stress. Accuracy of power-Doppler MCE for stenotic coronary arteries appears to be slightly higher than stress-echo wall-motion and similar to SPECT.
No takes yet. Share an insight, caveat, or question.
Rocchi et al. (2003) conducted a cross-sectional in Myocardial ischaemia and coronary artery stenosis (n=25). Power-Doppler myocardial contrast echocardiography (MCE) vs. 99Tc-Sestamibi SPECT and echo wall-motion analysis was evaluated on Accuracy for identification of stenotic (≥ 70%) coronary arteries as assessed by angiography. Power-Doppler MCE had 94% accuracy for identifying stenotic coronary arteries, which was similar to SPECT (94%) and higher than echo wall-motion analysis (83%).