Key result
Quantitative analysis of myocardial contrast echocardiography using pulse inversion demonstrated the best diagnostic agreement with SPECT (kappa 0.75) compared to other ultrasound modalities.
Why the study?
Does quantitative analysis of pulse inversion myocardial contrast echocardiography improve diagnostic agreement with SPECT compared to other ultrasound modalities in patients with suspected ischaemic heart disease?
Observational (n=23)
Does quantitative analysis of pulse inversion myocardial contrast echocardiography improve diagnostic agreement with SPECT compared to other ultrasound modalities in patients with suspected ischaemic heart disease?
Absolute Event Rate: 0.75% vs 0.62%
Quantitative densitometric analysis of pulse inversion myocardial contrast echocardiography provides the best diagnostic agreement with SPECT for evaluating suspected ischemic heart disease.
Supports quantitative pulse inversion MCE for ischemia detection; leaves open need for prospective outcome trials before clinical adoption.
Aims: This prospective study assesses the (1) feasibility of quantifying ultrasound myocardial perfusion studies based on the densitometric analysis of digital data and the (2) comparison of pulse inversion, second harmonic and harmonic power Doppler modalities with SPECT. Methods and Results:Twenty-three patients with suspected ischaemic heart disease had i.v.injections of Tc-Sestamibi and Optison during a dipyridamole stress test for echocardiography in pulse inversion, second harmonic and harmonic power Doppler mode.Analysis was (a) visual by scoring and (b) quantitative by densitometry of digital data for background subtracted myocardial opacification (a.u.) and normalized contrast effect (%).In the nine control patients, myocardial opacification at stress was greater (Pc0•002) than in the pathologic group (5•8 3•3 vs 2•6 2•5 a.u. in pulse inversion, 5•4 2•1 vs 2•4 1•8 in second harmonic and 7•1 3•7 vs 4•9 3•7 a.u. in harmonic power Doppler).In the pathologic group, normalized con-trast effect decreased significantly during stress (23•7 18•8 to 11•3 10•8%, P<0•003) only in pulse inversion.Kappa values for patient based diagnostic agreement with SPECT were 0•75 by pulse inversion, 0•62 by second harmonic and 0•52 by harmonic power Doppler for quantitative analysis, and 0•51, 0•37 and 0•35 respectively, for visual assessment.Conclusion: Myocardial contrast echocardiography should be analysed using densitometry of digital data.The new technique pulse inversion demonstrates best agreement with SPECT data.
No takes yet. Share an insight, caveat, or question.
VONBIBRA et al. (2002) conducted an observational in Suspected ischaemic heart disease (n=23). Pulse inversion myocardial contrast echocardiography vs. Second harmonic imaging and harmonic power Doppler was evaluated on Diagnostic agreement with SPECT (Kappa value). Quantitative analysis of myocardial contrast echocardiography using pulse inversion demonstrated the best diagnostic agreement with SPECT (kappa 0.75) compared to other ultrasound modalities.