Why the study?
Does quantitative analysis of digital data from pulse inversion myocardial contrast echocardiography improve diagnostic agreement with SPECT compared to visual assessment in patients with suspected ischaemic heart disease?
Does quantitative analysis of digital data from pulse inversion myocardial contrast echocardiography improve diagnostic agreement with SPECT compared to visual assessment in patients with suspected ischaemic heart disease?
Quantitative densitometric analysis of myocardial contrast echocardiography using pulse inversion yields the best diagnostic agreement with SPECT for suspected ischemic heart disease.
Supports quantitative pulse inversion MCE for improved SPECT agreement in suspected IHD; leaves open prospective outcome validation before practice change.
AIMS: This prospective study assesses the (1) feasibility of quantifying ultrasound myocardial perfusion studies based on the densitometric analysis of digital data and the (2) comparison of pulse inversion, second harmonic and harmonic power Doppler modalities with SPECT. METHODS AND RESULTS: Twenty-three patients with suspected ischaemic heart disease had i.v. injections of Tc-Sestamibi and Optison during a dipyridamole stress test for echocardiography in pulse inversion, second harmonic and harmonic power Doppler mode. Analysis was (a) visual by scoring and (b) quantitative by densitometry of digital data for background subtracted myocardial opacification (a.u.) and normalized contrast effect (%). In the nine control patients, myocardial opacification at stress was greater (P< or =0.002) than in the pathologic group (5. +/- 3.3 vs 2.6 +/- 2.5 a.u. in pulse inversion, 5.4 +/- 2.1 vs 2.4 +/- 1.8 in second harmonic and 7.1 +/- 3.7 vs 4.9 +/- 3.7 a.u. in harmonic power Doppler). In the pathologic group, normalized contrast effect decreased significantly during stress (23.7 +/- 18.8 to 11.3 +/- 10.8%, P<0.003) only in pulse inversion. Kappa values for patient based diagnostic agreement with SPECT were 0.75 by pulse inversion, 0.62 by second harmonic and 0.52 by harmonic power Doppler for quantitative analysis, and 0.51, 0.37 and 0.35 respectively, for visual assessment. CONCLUSION: Myocardial contrast echocardiography should be analysed using densitometry of digital data. The new technique pulse inversion demonstrates best agreement with SPECT data.
No takes yet. Share an insight, caveat, or question.
Bibra et al. (2002) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: