Key result
Pulsed tissue Doppler identified patients with CAD on SPECT, with normal SPECT patients having higher peak systolic velocity than those with ischaemia (18.9 vs 12.2 cm/s, P<0.001).
Why the study?
Does pulsed tissue Doppler imaging during dobutamine stress testing accurately detect myocardial ischemia compared to myocardial perfusion SPECT in patients with recent unstable angina?
Observational (n=26)
Does pulsed tissue Doppler imaging during dobutamine stress testing accurately detect myocardial ischemia compared to myocardial perfusion SPECT in patients with recent unstable angina?
Absolute Event Rate: 18.9% vs 12.2%
p-value: p=<0.001
Pulsed tissue Doppler during dobutamine stress testing can identify patients with CAD on SPECT, but is less accurate for identifying regional ischemia.
May support CAD detection on SPECT; leaves open accuracy for regional ischemia versus SPECT in unstable angina.
In order to compare the diagnostic ability of pulsed tissue Doppler and myocardial perfusion Single Photon Emission Computed Tomography (SPECT) in patients with a history of unstable coronary artery disease, CAD, 26 patients, 22 men and four women, age 47-76 years, were investigated in a prospective study, 5-10 day after an episode of unstable angina. Tissue Doppler and two-dimensional echocardiography were performed during dobutamine stress testing and myocardial scintigraphy after bicycle exercise and at rest. Patients with a normal SPECT had higher peak systolic velocity during dobutamine infusion, 18.9 +/- 4.1 cm s(-1), than patients with ischaemia, 12.2 +/- 3.8 cm s(-1) (P<0.001) or scar, 8.8 +/- 3.0 cm s(-1) (P<0.01). In a territorial analysis the difference in peak systolic velocity between areas with a normal and abnormal SPECT was less apparent. Failure to achieve >/=13 cm s(-1) in mean-peak systolic velocity was the most accurate criterion for detection of significant CAD on SPECT. We conclude that pulsed tissue Doppler can be used for objective quantification of left ventricular wall motion during dobutamine stress testing and for identification of patients with CAD on SPECT but not for identification of regional ischaemia.
No takes yet. Share an insight, caveat, or question.
Blomstrand et al. (2004) conducted an observational in Unstable coronary artery disease (n=26). Pulsed tissue Doppler imaging vs. Myocardial perfusion SPECT was evaluated on Peak systolic velocity during dobutamine infusion (p=<0.001). Pulsed tissue Doppler identified patients with CAD on SPECT, with normal SPECT patients having higher peak systolic velocity than those with ischaemia (18.9 vs 12.2 cm/s, P<0.001).