Key result
LBBAP achieves ~86% implantation success without acute procedural complications during dual-chamber pacemaker placement.
Why the study?
Right ventricular pacing causes electrical dyssynchrony and adverse cardiac remodelling, while left bundle branch area pacing preserves ventricular synchrony through the His–Purkinje system.
Observational (n=7)
No
LBBAP is a feasible and safe physiological pacing strategy for patients undergoing dual-chamber pacemaker implantation, yielding favorable short-term electrical outcomes.
Supports feasibility in dual-chamber devices; leaves open confirmation of long-term outcomes in randomized trials.
Right ventricular pacing leads to nonphysiological ventricular activation and causes electrical dyssynchrony and adverse cardiac remodelling. Left bundle branch area pacing (LBBAP) responsible for physiological pacing strategy that preserves synchrony of ventricles by engaging the His–Purkinje system. The objective of the study was to evaluate the procedural feasibility and outcomes of LBBAP in patients undergoing dual chamber pacemaker implantation. In this single center, retrospective observational case series, seven patients undergoing dual chamber pacemaker implantation with LBBAP between January 2025 and January 2026 were included. Procedural success was defined as achievement of stable LBBAP with acceptable pacing parameters and significant QRS narrowing. Electrical parameters include pacing threshold, sensing amplitudes, and lead impedance, were assessed at implantation and prior to discharge. A total of seven patients underwent LBBAP. Successful LBBAP implantation was achieved in 6 of 7 patients (85.7%). The mean procedure time was 75 ± 15 min, with fluoroscopy time of 8 ± 3 min. LBBAP caused important QRS narrowing with stable lead parameters. Mean pacing thresholds of RA and RV were low, measuring 0.66 V in right atrium (RA) and 0.49 V in right ventricle (RV), showing stable lead activity with sufficient sensing and impedance values. No acute procedural complications, including lead dislodgement, cardiac perforation, or pneumothorax, were observed. LBBAP is a feasible and safe physiological pacing strategy in those patients undergoing dual chamber pacemaker implantation, demonstrating high procedural success and favourable short term electrical outcomes. Larger prospective studies are warranted to evaluate long term clinical benefits.
No takes yet. Share an insight, caveat, or question.
Bhole et al. (2026) conducted an observational in Dual chamber pacemaker implantation (n=7). Left bundle branch area pacing (LBBAP) was evaluated on Procedural success (achievement of stable LBBAP with acceptable pacing parameters and significant QRS narrowing). Left bundle branch area pacing achieved successful implantation in 85.7% of patients undergoing dual-chamber pacemaker placement, with stable parameters and no acute procedural complications.