Key result
Elevated hs-cTnI linked to ~2.7-fold higher risk of incident MI during diagnostic coronary angiography.
Why the study?
The clinical significance of high-sensitivity troponin I concentrations in patients without acute myocardial infarction undergoing diagnostic coronary angiography requires clarification.
Cohort (n=991)
No
Hazard Ratio: 2.68 (95% CI 1.86–3.85)
Absolute Event Rate: 27% vs 9%
p-value: p=<0.001
May aid post-angiography risk stratification in stable patients; extends prognostic data but leaves open whether it guides therapy.
Background The meaning of high‐sensitivity troponin I (hsTnI) concentrations in patients without acute myocardial infarction ( MI ) requires clarity. We hypothesized that among patients referred for diagnostic coronary angiography without acute MI , hsTnI concentrations would correlate with prevalent coronary artery disease ( CAD ) and predict incident cardiovascular events and mortality. Methods and Results We measured hsTnI using a single‐molecule counting assay (99th percentile, 6 ng/L) in samples from 991 patients obtained at the time of angiography. Concentrations of hsTnI were assessed relative to the severity of CAD and prognosis during mean follow‐up of 3.7 years. Median hsTnI concentration was 4.19 ng/L; 38% of patients had hsTnI concentrations ≥99th percentile. Across increasing hsTnI quartiles, patients had higher prevalence of angiographic CAD ; in multivariate models, hsTnI ≥99th percentile independently predicted obstructive CAD (odds ratio: 2.57; P <0.001) and incident MI (hazard ratio [ HR ]: 2.68; P <0.001), cardiovascular death ( HR: 2.29; P =0.001), and all‐cause death ( HR: 1.84; P =0.004). In those with >70% coronary stenosis, hsTnI ≥99th percentile independently predicted incident MI ( HR: 1.87; P =0.01), cardiovascular mortality ( HR: 2.74; P =0.001), and the composite end point of MI and all‐cause death ( HR: 2.06; P <0.001). In participants with coronary stenosis <70%, hsTnI ≥99th percentile even more strongly predicted incident MI ( HR : 8.41; P <0.001), cardiovascular mortality ( HR : 3.60; P =0.03), and the composite end point of MI and all‐cause death ( HR: 3.62; P <0.001). Conclusions In a large prospective cohort of patients who were free of prevalent MI and undergoing diagnostic coronary angiography, hsTnI concentrations were associated with higher prevalence of CAD and predicted incident MI , cardiovascular death, and all‐cause death. Clinical Trial Registration URL : http://www.clinicaltrials.gov . Unique identifier: NCT 00842868.
No takes yet. Share an insight, caveat, or question.
McCarthy et al. (2018) conducted a cohort in Referred for diagnostic coronary angiography without acute myocardial infarction (n=991). High-sensitivity troponin I (hsTnI) ≥99th percentile vs. hsTnI <99th percentile was evaluated on Incident myocardial infarction (HR 2.68, 95% CI 1.86-3.85, p=<0.001). In patients undergoing diagnostic coronary angiography without acute myocardial infarction, high-sensitivity troponin I concentrations ≥99th percentile independently predicted incident myocardial infarction (HR 2.68).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: